TY - JOUR U1 - Zeitschriftenartikel, wissenschaftlich - begutachtet (reviewed) A1 - Seyringer, Dana A1 - Sagmeister, Martin A1 - Maese-Novo, Alejandro A1 - Eggeling, Moritz A1 - Rank, Elisabet A. A1 - Muellner, Paul A1 - Hainberger, Rainer A1 - Drexler, Wolfgang A1 - Vlaskovic, Marko A1 - Zimmermann, Horst A1 - Meinhardt, Gerald A1 - Kraft, Jochen T1 - Technological verification of size-optimized 160-channel silicon nitride-based AWG-spectrometer for medical applications JF - Applied Physics B N2 - We present the technological verification of a size-optimized 160-channel, 50-GHz silicon nitride-based AWG-spectrometer. The spectrometer was designed for TM-polarized light with a central wavelength of 850 nm applying our proprietary “AWG-Parameters” tool. For the simulations of AWG layout, the WDM PHASAR photonics tool from Optiwave was used. The simulated results show satisfying optical properties of the designed AWG-spectrometer. However, the high-channel count causes a large AWG size with standard design approaches. To solve this problem we designed a special taper enabling the reduction of AWG structure by about 15% while keeping the same optical properties. The AWG design was fabricated and the measured spectra not only confirm the proposed size-reduction but also the improvement of optical properties of the size-optimized AWG. Y1 - 2019 U6 - https://doi.org/10.1007/s00340-019-7192-1 DO - https://doi.org/10.1007/s00340-019-7192-1 VL - 125. Jg. IS - H. 6 SP - 10 S1 - 10 ER -