Refine
Year of publication
Document Type
- Article (288) (remove)
Institute
- Forschungszentrum Mikrotechnik (102)
- Forschungszentrum Business Informatics (66)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (52)
- Technik | Engineering & Technology (52)
- Forschungszentrum Energie (49)
- Wirtschaft (33)
- Josef Ressel Zentrum für Materialbearbeitung (15)
- Soziales & Gesundheit (14)
- Didaktik (mit 31.03.2021 aufgelöst; Integration ins TELL Center) (12)
- Forschungszentrum Human Centred Technologies (10)
Language
- English (288) (remove)
Keywords
- Laser ablation (8)
- Evolution strategy (5)
- Volatile organic compounds (5)
- Y-branch splitter (5)
- Demand side management (4)
- mHealth (4)
- AWG (3)
- Demand response (3)
- Desalination (3)
- Evolution strategies (3)
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.
X-ray micro tomography of three-dimensional embroidered current collectors for lithium-ion batteries
(2016)
In this paper, low-loss Y-branch splitters up to 128 splitting ratio are designed, simulated, and optimized by using 2D beam propagation method in OptiBPM tool by Optiwave. For an optical waveguide, a silica-on-silicon material platform is used. The splitters were designed as a planar structure for a telecommunication operating wavelength of 1.55 m. According to the minimum insertion loss and minimum non-uniformity, the optimum length for each Y-branch is determined. The influence of the pre-defined S-Bend waveguide shapes (Arc, Cosine, Sine) and of the waveguide core size reduction on the splitter performance has been also studied. The obtained simulation results of all designed splitters with different S-Bend shape waveguides together with the different waveguide core sizes are discussed and compared with each other.
Greater specific energy densities in lithium-ion batteries can be achieved by using three-dimensional (3D) porous current collectors, which allow for greater areal mass loadings of the electroactive material. In this paper, we present the use of embroidered current collectors for the preparation of thick, pouch-type Li-ion batteries. Experiments were performed on LiFePO 4 (LFP) water-based slurries using styrene-butadiene rubber (SBR) as binder and sodium carboxymethyl cellulose (CMC) as thickener, and formulations of different rheological characteristics were investigated. The electrochemical performance (cyclic voltammetry, rate capability) and morphological characteristics of the LFP half-pouch cells (X-ray micro computed tomography and scanning electron microscopy) were compared between the formulations. An optimum electrode formulation was identified, and a mechanism is proposed to explain differences between the formulations. With the optimum electrode formulation, 350 µm casted electrodes with high mechanical stability were achieved. Electrodes exhibited 4–6 times greater areal mass loadings (4–6 mAh cm −2 ) and 50% greater electroactive material weight than with foils. In tests of half- and full-pouch embroidered cells, a 50% capacity utilization at 1C-rate and 11% at 2C-rate were observed, with a full recovery at C/5-rate. The cycling stability was also maintained over 55 cycles.
If left uncontrolled, electric vehicle charging poses severe challenges to distribution grid operation. Resulting issues are expected to be mitigated by charging control. In particular, voltage-based charging control, by relying only on the local measurements of voltage at the point of connection, provides an autonomous communication-free solution. The controller, attached to the charging equipment, compares the measured voltage to a reference voltage and adapts the charging power using a droop control characteristic. We present a systematic study of the voltage-based droop control method for electric vehicles to establish the usability of the method for all the currently available residential electric vehicle charging possibilities considering a wide range of electric vehicle penetrations. Voltage limits are evaluated according to the international standard EN50160, using long-term load flow simulations based on a real distribution grid topology and real load profiles. The results achieved show that the voltage-based droop controller is able to mitigate the under voltage problems completely in distribution grids in cases either deploying low charging power levels or exhibiting low penetration rates. For high charging rates and high penetrations, the control mechanism improves the overall voltage profile, but it does not remedy the under voltage problems completely. The evaluation also shows the controller’s ability to reduce the peak power at the transformer and indicates the impact it has on users due to the reduction in the average charging rates. The outcomes of the paper provide the distribution grid operators an insight on the voltage-based droop control mechanism for the future grid planning and investments.
Violation-mitigation-based method for PV hosting capacity quantification in low voltage grids
(2022)
Hosting capacity knowledge is of great importance for distribution utilities to assess the amount of PV capacity possible to accommodate without troubling the operation of the grid. In this paper, a novel method to quantify the hosting capacity of low voltage grids is presented. The method starts considering a state of fully exploited building rooftop solar potential. A downward process is proposed - from the starting state with expected violations on the grid operation to a state with no violations. In this process, the installed PV capacity is progressively reduced. The reductions are made sequentially and selectively aiming to mitigate specific violations: nodes overvoltage, lines overcurrent and transformer overloading. Evaluated on real data of fourteen low voltage grids from Austria, the method proposed exhibits benefits in terms of higher hosting capacities and lower computational costs compared to stochastic methods. Furthermore, it also quantifies hosting capacity expansions achievable by overcoming the effect of the violations. The usage of a potential different from solar rooftops is also presented, demonstrating that a user-defined potential allows to quantify the hosting capacity in a more general setting with the method proposed.
Objectives: The MetabQoL 1.0 is the first disease-specific health related quality of life (HrQoL) questionnaire for patients with intoxication-type inherited metabolic disorders. Our aim was to assess the validity and reliability of the MetabQoL 1.0, and to investigate neuropsychiatric burden in our patient population. Methods: Data from 29 patients followed at a single center, aged between 8 and 18 years with the diagnosis of methylmalonic acidemia (MMA), propionic acidemia (PA) or isovaleric acidemia (IVA), and their parents were included. The Pediatric Quality of Life Inventory (PedsQoL) was used to evaluate the validity and reliability of MetabQoL 1.0.
Results: The MetabQoL 1.0 was shown to be valid and reliable (Cronbach's alpha: 0.64–0.9). Fourteen out of the 22 patients (63.6%) formally evaluated had neurological findings. Of note, 17 out of 20 patients (85%) had a psychiatric disorder when evaluated formally by a child and adolescent psychiatrist. The median mental scores of the MetabQoL 1.0 proxy report were significantly higher than those of the self report (p = 0.023). Patients with neonatal-onset disease had higher MetabQoL 1.0 proxy physical (p = 0.008), mental (p = 0.042), total scores (p = 0.022); and self report social (p = 0.007) and total scores (p = 0.043) than those with later onset disease.
Conclusions: This study continues to prove that the MetabQoL 1.0 is an effective tool to measure what matters in intoxication-type inherited metabolic disorders. Our results highlight the importance of clinical assessment complemented by patient reported outcomes which further expands the evaluation toolbox of inherited metabolic diseases.
We have investigated the ablation behaviour of single crystal SrTiO3 <100> with focus on the influence of the pulse duration at a wavelength of 248 nm. The experiments were performed with KrF-excimer lasers with pulse durations of 34 ns and 500 fs, respectively. Femtosecond-ablation turns out to be more efficient by one order of magnitude and to eliminate the known problem of cracking of SrTiO3 during laser machining with longer pulses. In addition, the cavities ablated with femtosecond pulses display a smoother surface with no indication of melting and well-defined, sharp edges. These effects can be explained by the reduced thermal shock effect on the material by using ultrashort pulses.