Refine
Year of publication
- 2022 (22) (remove)
Document Type
- Article (22) (remove)
Institute
Has Fulltext
- no (22) (remove)
Keywords
- Elternschaft (2)
- Gender (2)
- Gleichstellung (2)
- New Work und New Leadership (2)
- Soziale Arbeit (2)
- 3D MMI splitter (1)
- 3D Y-branch splitter (1)
- AWG (1)
- Beobachtung (1)
- Compassionate curriculum (1)
In this paper, the design of three-dimensional configuration of Y-branch splitter is compared with Multimode Interference splitter. Both splitters use the IP-Dip polymer as a standard material for 3D laser lithography. The optical properties of the splitters for both approaches are discussed and compared.
The paper deals with designing and numerical modelling a 2 x 2 optical switch for photonic integrated circuits based on 2 x 2 MMI elements and phase modulators. The 2 x 2 optical switch was modelled in the RsoftCAD with the simulation tool BeamPROP. The 2 x 2 optical switch is a common element for creating more complex 1 x N or N x N optical switches in all-optical signal processing.
In this work, we investigated the influence of different etch depths of the rib waveguides on the performance of SiN-based AWGs. For this purpose, an 8-channel 100 GHz AWG was designed for a center wavelength of 850 nm. The design parameters entered were calculated using the AWG-Parameters tool. The simulations were performed with a commercial photonic tool PHASAR from Optiwave. The simulated performance was evaluated using the AWG-Analyzer tool. For the AWG design, we used three identical rib waveguides with different etch depths to simulate possible etch imperfection. The simulations show the wavelength shift and degradation of the AWG performance.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2022)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
Sie werden beobachtet
(2022)
Wahrheit braucht Vertrauen
(2022)
Die Arbeitswelt von morgen
(2022)