Refine
Year of publication
- 2021 (76) (remove)
Document Type
- Article (32)
- Conference Proceeding (27)
- Book (6)
- Report (4)
- Part of a Book (3)
- Other (3)
- Part of Periodical (1)
Institute
- Forschungszentrum Mikrotechnik (19)
- Soziales & Gesundheit (17)
- Forschungszentrum Human Centred Technologies (12)
- Wirtschaft (12)
- Forschungsgruppe Empirische Sozialwissenschaften (11)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (9)
- Forschungszentrum Business Informatics (9)
- Technik | Engineering & Technology (9)
- Forschungszentrum Digital Factory Vorarlberg (3)
- Forschungszentrum Energie (2)
Language
- English (41)
- German (33)
- Multiple languages (2)
Is part of the Bibliography
- yes (76) (remove)
Keywords
- Entscheidung (5)
- MMI splitters (4)
- Soziale Arbeit (4)
- Y-branch splitter (4)
- Arrayed waveguide gratings (2)
- Assistenztechnologien (2)
- Cloud manufacturing (2)
- Demand response (2)
- Forschung (2)
- Gesundheit (2)
Gewalt in der Pflege
(2021)
Studien zeigen, dass das medizinisch/pflegerische Personal nach Polizei und Sicherheitsleuten unter allen Berufen am zweithäufigsten am Arbeitsplatz von Aggressions- und Gewaltereignissen betroffen sind und dies hat einen negativen Einfluss auf die Berufszufriedenheit und die Gesundheit der betroffenen Mitarbeiter:innen.
Die Studie „Gewalt in der Pflege“ begründet auf repräsentativer Basis ein Monitoring über das Ausmaß von Gewalt gegenüber Pflegenden in Vorarlberger Pflege- und Betreuungseinrichtungen. Für die Analyse wurde in Anlehnung an bestehende Erhebungsinstrumente in verbale Gewalt (inkl. Drohungen), körperliche Gewalt und sexuelle Gewalt unterschieden.
80 % der Befragten gaben an bereits mindestens einmal in ihrem Berufsleben mit Gewalt konfrontiert gewesen zu sein. 44,1 % von ihnen waren Opfer körperlicher Gewalt in verschiedenen Schweregraden. Auch die Prävalenz von sexueller Gewalt ist in den Pflegeheimen als hoch einzustufen, wobei der Großteil der betroffenen Mitarbeiter:innen Frauen sind. Die Hauptquelle der Gewalt sind die Bewohner:innen, gefolgt von den Angehörigen. Es können verschiedene Gründe und Ursachen für die Gewalt ausgemacht werden. Da sind zunächst gesellschaftliche Entwicklungen, wie ein gesteigerter Erwartungsdruck an die Pflegequalität bei gleichbleibenden Rahmenbedingungen, das zunehmende schwerere Krankheitsbild Bewohner:innen von Alters- und Pflegeheimen, sowie eine hohe Belegungszahl zu nennen. Gewalterfahrungen egal welcher Art sind eine Belastung für das Pflegepersonal.
To create a map of an unknown area, autonomous robots must follow a strategy to explore the area without knowing the optimal paths to reduce the time needed to map the whole area. To reduce the time to accomplish this task, multiple robots can work together to create a map in a more efficient way. However, without proper coordination, the time a team of autonomous robots needs to explore the unknown area can exceed the time needed by a single robot. To counteract the challenges, a shared infrastructure is needed which extracts useful information for the individual robots out of the shared information of all robots so the exploration can be coordinated. These measures introduce new challenges to the system, concerning the load of the communication infrastructure as well as the overall task of exploring and mapping becoming dependent on the correct communication and robustness of the shared team infrastructure. Therefore, the amount of communication and dependency of each individual robot of the rest of the other robots of the team must be reduced to ensure that the robots can continue working even if the communication with the shared infrastructure fails.
If left uncontrolled, electric vehicle charging poses severe challenges to distribution grid operation. Resulting issues are expected to be mitigated by charging control. In particular, voltage-based charging control, by relying only on the local measurements of voltage at the point of connection, provides an autonomous communication-free solution. The controller, attached to the charging equipment, compares the measured voltage to a reference voltage and adapts the charging power using a droop control characteristic. We present a systematic study of the voltage-based droop control method for electric vehicles to establish the usability of the method for all the currently available residential electric vehicle charging possibilities considering a wide range of electric vehicle penetrations. Voltage limits are evaluated according to the international standard EN50160, using long-term load flow simulations based on a real distribution grid topology and real load profiles. The results achieved show that the voltage-based droop controller is able to mitigate the under voltage problems completely in distribution grids in cases either deploying low charging power levels or exhibiting low penetration rates. For high charging rates and high penetrations, the control mechanism improves the overall voltage profile, but it does not remedy the under voltage problems completely. The evaluation also shows the controller’s ability to reduce the peak power at the transformer and indicates the impact it has on users due to the reduction in the average charging rates. The outcomes of the paper provide the distribution grid operators an insight on the voltage-based droop control mechanism for the future grid planning and investments.