Refine
Year of publication
Document Type
- Conference Proceeding (137)
- Article (104)
- Preprint (4)
- Part of a Book (3)
- Doctoral Thesis (2)
- Book (1)
- Habilitation (1)
- Other (1)
Institute
- Forschungszentrum Mikrotechnik (253) (remove)
Language
- English (247)
- German (5)
- Multiple languages (1)
Keywords
- Laser ablation (11)
- Y-branch splitter (11)
- arrayed waveguide gratings (11)
- photonics (8)
- integrated optics (6)
- Arrayed waveguide gratings (5)
- MMI splitter (5)
- OCT (5)
- insertion loss (5)
- AWG (4)
The utilization of lasers in dentistry expands greatly in recent years. For instance, fs-lasers are effective for both drilling and caries prevention, while cw-lasers are useful for adhesive hardening. A cutting-edge application of lasers in dentistry is the debonding of veneers. While there are pre-existing tools for this purpose, there is still potential for improvement. Initial efforts to investigate laser assisted debonding mechanisms with measurements of the optical and mechanical properties of teeth and prosthetic ceramics are presented. Preliminary tests conducted with a laser system used for debonding that is commercially available showed differences in the output power set at the systems console to that at specified distances from the handpiece. Furthermore, the optical properties of the samples (human teeth and ceramics) were characterised. The optical properties of the ceramics should closely resemble those of teeth in terms of look and feel, but they also influence the laser assisted debonding technique and thus must be taken into account. In addition first attempts were performed to investigate the mechanical properties of the samples by means of pump-probe-elastography under a microscope. By analyzing the sample surface up to 20 ns after a fs-laser pulse impact, pressure and shock waves could be detected, which can be utilized to determine the elastic constants of specific materials. Together such investigations are needed to shape the basis for a purely optical approach of debonding of veneers utilizing acoustic waves.
This paper presents a project developed at the K.S.Rangasamy College of Technology (Tamilnadu,India) aimed at designing, implementing, and testing an autonomous multipurpose vehicle with safe, efficient, and economic operation. This autonomous vehicle moves through the crop lines of a Agricultural land and performs tasks that are tedious and/or hazardous to the farmers. First, it has been equipped for spraying, but other configurations have also been designed, such as: a seeding ,plug platform to reach the top part of the plants to perform different tasks (pruning, harvesting, etc.), and a trailer to transport the fruits, plants, and crop waste.
Modern portable electronic devices have seen component heat load increasing, while the space available for heat dissipation has decreased. This requires the thermal management system to be optimized to attain the high performance heat sink. Heat sinks plays a major role for dissipating heat in electronic devices. Phase change material (PCM) is used to enhance the heat dissipation in heat sink. This paper reports the results of an experimental investigation of the performance of Pin fin heat sinks filled with phase change materials for thermal management of electronic devices. The experimental set ups are prepared with the graphical programming language with Lab VIEW (Laboratory Virtual Instruments for Engineering Workbench. Three different types of Pin fin Heat sink with and without PCM are investigated based on different operational timings and the temperature is acquired with the help of Data Acquisition Card (DAQ). The results indicated that the inclusion of the PCM could stabilize the temperature for a longer period and reduce the heating rates and peak temperatures of heat sink with increasing the number of fins can enhance the thermal performance of electronic devices.
Signatures of the optical stark effect on entangled photon pairs from resonantly-pumped quantum dots
(2023)
Two-photon resonant excitation of the biexciton-exciton cascade in a quantum dot generates highly polarization-entangled photon pairs in a near-deterministic way. However, the ultimate level of achievable entanglement is still debated. Here, we observe the impact of the laser-induced ac-Stark effect on the quantum dot emission spectra and on entanglement. For increasing pulse-duration-to-lifetime ratios and pump powers, decreasing values of concurrence are recorded. Nonetheless, additional contributions are still required to fully account for the observed below-unity concurrence.
Strain-induced dynamic control over the population of quantum emitters in two-dimensional materials
(2023)
The discovery of quantum emitters in two-dimensional materials has triggered a surge of research to assess their suitability for quantum photonics. While their microscopic origin is still the subject of intense studies, ordered arrays of quantum emitters are routinely fabricated using static strain-gradients, which are used to drive excitons toward localized regions of the 2D crystals where quantum-light-emission takes place. However, the possibility of using strain in a dynamic fashion to control the appearance of individual quantum emitters has never been explored so far. In this work, we tackle this challenge by introducing a novel hybrid semiconductor-piezoelectric device in which WSe2 monolayers are integrated onto piezoelectric pillars delivering both static and dynamic strains. Static strains are first used to induce the formation of quantum emitters, whose emission shows photon anti-bunching. Their excitonic population and emission energy are then reversibly controlled via the application of a voltage to the piezoelectric pillar. Numerical simulations combined with drift-diffusion equations show that these effects are due to a strain-induced modification of the confining-potential landscape, which in turn leads to a net redistribution of excitons among the different quantum emitters. Our work provides relevant insights into the role of strain in the formation of quantum emitters in 2D materials and suggests a method to switch them on and off on demand.
Synthetic polymers, such as polyamide (PA), inherently possess a moderate number of surface functionalities compared to natural polymers, which negatively impacts the uniformity of metallic coatings obtained through wet-chemical methods like electroless plating. The paper presents the use of a siloxane interlayer formed from the condensation of the hydrolyzed 3-triethoxysilylpropyl succinic anhydride (TESPSA) precursor as a strategy to modify the surface properties of polyamide 6.6 (PA66) fabrics and improve the uniformity of the copper surface coating. The application of the siloxane intermediate coating demonstrates a significant improvement in electrical conductivity, up to 20 times higher than fabrics without the interlayer. The morphology of the coatings was investigated using scanning electron (SEM) and laser confocal scanning microscopy (LSM). In addition, dye adsorption, flexural rigidity, air permeability and contact angle measurements were conducted to monitor the change in the PA66 properties after the siloxane functionalization.
Experimental multi-state quantum discrimination in the frequency domain with quantum dot light
(2022)
The quest for the realization of effective quantum state discrimination strategies is of great interest for quantum information technology, as well as for fundamental studies. Therefore, it is crucial to develop new and more efficient methods to implement discrimination protocols for quantum states. Among the others, single photon implementations are more advisable, because of their inherent security advantage in quantum communication scenarios. In this work, we present the experimental realization of a protocol employing a time-multiplexing strategy to optimally discriminate among eight non-orthogonal states, encoded in the four-dimensional Hilbert space spanning both the polarization degree of freedom and photon energy. The experiment, built on a custom-designed bulk optics analyser setup and single photons generated by a nearly deterministic solid-state source, represents a benchmarking example of minimum error discrimination with actual quantum states, requiring only linear optics and two photodetectors to be realized. Our work paves the way for more complex applications and delivers a novel approach towards high-dimensional quantum encoding and decoding operations.
A quantum-light source that delivers photons with a high brightness and a high degree of entanglement is fundamental for the development of efficient entanglement-based quantum-key distribution systems. Among all possible candidates, epitaxial quantum dots are currently emerging as one of the brightest sources of highly entangled photons. However, the optimization of both brightness and entanglement currently requires different technologies that are difficult to combine in a scalable manner. In this work, we overcome this challenge by developing a novel device consisting of a quantum dot embedded in a circular Bragg resonator, in turn, integrated onto a micromachined piezoelectric actuator. The resonator engineers the light-matter interaction to empower extraction efficiencies up to 0.69(4). Simultaneously, the actuator manipulates strain fields that tune the quantum dot for the generation of entangled photons with fidelities up to 0.96(1). This hybrid technology has the potential to overcome the limitations of the key rates that plague current approaches to entanglement-based quantum key distribution and entanglement-based quantum networks. Introduction
Beyond the Four-Level Model: Dark and Hot States in Quantum Dots Degrade Photonic Entanglement
(2023)
Entangled photon pairs are essential for a multitude of quantum photonic applications. To date, the best performing solid-state quantum emitters of entangled photons are semiconductor quantum dots operated around liquid-helium temperatures. To favor the widespread deployment of these sources, it is important to explore and understand their behavior at temperatures accessible with compact Stirling coolers. Here we study the polarization entanglement among photon pairs from the biexciton–exciton cascade in GaAs quantum dots at temperatures up to ∼65 K. We observe entanglement degradation accompanied by changes in decay dynamics, which we ascribe to thermal population and depopulation of hot and dark states in addition to the four levels relevant for photon pair generation. Detailed calculations considering the presence and characteristics of the additional states and phonon-assisted transitions support the interpretation. We expect these results to guide the optimization of quantum dots as sources of highly entangled photons at elevated temperatures.
This study presents different approaches to increase the sensing area of NiO based semiconducting metal oxide gas sensors. Micro- and nanopatterned laser induced periodic surface structures (LIPSS) are generated on silicon and Si/SiO2 substrates. The surface morphologies of the fabricated samples are examined by FE SEM. We select the silicon samples with an intermediate Si3N4 layer due to its superior isolation quality over the thermal oxide for evaluating the hydrogen and acetone sensitivity of a NiO based test sensor.
Whether at the intramolecular or cellular scale in organisms, cell-cell adhesion adapt to external mechanical cues arising from the static environment of cells and from dynamic interactions between neighboring cells. Cell-cell adhesions need to resist detachment forces to secure the integrity and internal organization of organisms. In the past, various techniques have been developed to characterize adhesion properties of molecules and cells in vitro, and to understand how cells sense and probe their environment. Atomic force microscopy and dual-pipette aspiration, where cells are mainly present in suspension, are common methods for studying detachment forces of cell-cell adhesions. How cell-cell adhesion forces are developed for adherent and environment-adapted cells, however, is less clear. Here, we designed the Cell-Cell Separation Device (CC-SD), a microstructured substrate that measures both intercellular forces and external stresses of cells towards the matrix. The design is based on micropillar arrays originally designed for cell traction-force measurements. We designed PDMS micropillar-blocks, to which cells could adhere and be able to connect to each other across the gap. Controlled stretching of the whole substrate changed the distance between blocks and increased gap size. That allowed us to apply strains to cell-cell contacts, eventually leading to cell-cell adhesion detachment, which was measured by pillar deflections. The CC-SD provided an increase of the gap between the blocks of up to 2.4-fold, which was sufficient to separate substrate-attached cells with fully developed F-actin network. Simultaneously measured pillar deflections allowed us to address cellular response to the intercellular strain applied. The CC-SD thus opens up possibilities for the analysis of intercellular force detachments and sheds light on the robustness of cell-cell adhesions in dynamic processes in tissue development.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2023)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.
Parametric anti-resonance is a phenomenon that occurs in systems with at least two degrees of freedom; this can be achieved by periodically exciting some parameters of the system. The effect of this properly tuned periodicity is to increase the dissipation in the system, which leads to a raising in the effective damping of vibrations. This contribution presents the design of an open-loop control to reduce the settling time using the anti-resonance concept. The control signal consists of a quasi-periodic signal capable of transferring the system’s oscillations from one mode to another mode of the system. The general averaging technique is used to characterize the dynamics, particularly the so-called slow dynamics of motion. With this analysis, the control signal is designed for the potential application of a microelectromechanical sensor arrangement; for this specific example, up to 96.8% reduction of settling time is achieved.
In this work, parametric excitation is introduced in a fully balanced flexible rotor mounted on two identical active gas foil bearings. The active gas foil bearings change the top foil shape harmonically with a specific amplitude and frequency. The deformable foil shape is approximated by an analytical function, while the gas pressure distribution is evaluated by the numerical solution of the Reynolds equation for compressible flow. The harmonic variation of the foil shape generates a respective variation in the bearings’ stiffness and damping properties and the system experiences parametric resonances and antiresonances in specific excitation frequencies. The nonlinear gas bearing forces generate bifurcations in the solutions of the system at certain rotating speeds and excitation frequencies; period doubling and Neimark-Sacker bifurcations are noticed in the examined system, and their progress is evaluated as the two bifurcation parameters (rotating speed and parametric excitation frequency) are changed, though a codimension-2 numerical continuation of limit cycles. It is found that at specific range of excitation frequency there are parametric anti-resonances and the bifurcations collide and vanish. Therefore, a bifurcation-free operating range is established and the system can operate stable at a wide speed range.
By a simple femtosecond laser process, we fabricated metal-oxide/gold composite films for electrical and optical gas sensors. We designed a dripple wavelength AWG-spectrometer, matched to the plasma absorption wavelength region of the composite films. H2/CO absorptions fit well with the AWG design for multi gas detection sensor arrays
The main aims of this work are the validation of the developed process of gluing a single-mode optical fiber array with a photonic chip and the selection of a more suitable adhesive from the two adhesives being compared. An active alignment system was used for adjusting the two optical fiber arrays to a photonics chip. The gluing was done by two compared UV curable adhesives applied in the optical path. The insertion losses of glued coupling were measured and investigated at two discrete wavelengths 1310 nm and 1550 nm during temperature testing in the climatic chamber according to Telcordia GR_1209_Corei04 [3]. The measurement, investigation, and comparison of insertion losses of the glued coupling at the spectral band from 1530 nm to 1570 nm were done immediately after gluing process and after three temperature cycles in the climatic chamber with one month delay.
The production of liquid-gas mixtures with desired properties still places high demands on process technology and is usually realized in bubble columns. The physical calculation models used have individual dimensionless factors which, depending on the application, are only valid for small ranges consisting of flow velocity, nozzle geometry and test setup. An iterative but time-consuming design of such dispersion processes is used in industry for producing a liquid-gas mixture according to desired requirements. In the present investigation, we accelerate the necessary design loops by setting up a physical model, which consists of several subsystems that are enriched by dedicated experiments to realize liquid-gas dispersions with low volume fraction and small air bubble diameters in oil. Our approach allows the extraction of individual dimensionless factors from maps of the introduced subsystems. These maps allow for targeted corrective measures of a production process for keeping the quality. The calculation-based approach avoids the need for performing iterative design loops. Overall, this approach supports the controlled generation of liquid-gas mixtures.
In this paper, a 256-channel, 10-GHz arrayed waveguide gratings demultiplexer for ultra-dense wavelength division multiplexing was designed using an in-house developed tool called AWG-Parameters. The AWG demultiplexer was designed for a central wavelength of 1550 nm and the structure was simulated in PHASAR tool from Optiwave. Two different AWG designs were developed and the influence of the design parameters on the AWG performance was studied.
Design, simulation, and optimization of the 1×4 optical three-dimensional multimode interference splitter using IP-Dip polymer as a core and polydimethylsiloxane (PDMS) Sylgard 184 as a cladding is demonstrated. The splitter was simulated by using beam propagation method in BeamPROP simulation module of RSoft photonic tool and optimized for an operating wavelength of 1.55 μm . According to the minimum insertion loss, the dimensions of the splitter were optimized for a waveguide with a core size of 4×4 μm2 . The objective of the study is to create the design for fabrication by three-dimensional direct laser writing optical lithography.