Refine
Year of publication
Document Type
- Article (104) (remove)
Institute
- Forschungszentrum Mikrotechnik (104) (remove)
Language
- English (102)
- German (1)
- Multiple languages (1)
Keywords
- Laser ablation (8)
- Y-branch splitter (5)
- AWG (3)
- AWG-spectrometer (2)
- Dissolution rate monitor (2)
- Femtosecond laser (2)
- High-speed optical techniques (2)
- Laser beam machining (2)
- Levodopa (2)
- Microneedle (2)
In this paper, we propose and simulate a new type of three-dimensional (3D) optical splitter based on multimode interference (MMI) for the wavelength of 1550 nm. The splitter was proposed on the square basis with the width of 20 x 20 µm2 using the IP-Dip polymer as a standard material for 3D laser lithography. We present the optical field distribution in the proposed MMI splitter and its integration possibility on optical fiber. The design is aimed to the possible fabrication process using the 3D laser lithography for forthcoming experiments.
We present a new concept of 3D polymer-based 1 × 4 beam splitter for wavelength splitting around 1550 nm. The beam splitter consists of IP-Dip polymer as a core and polydimethylsiloxane (PDMS) Sylgard 184 as a cladding. The splitter was designed and simulated with two different photonics tools and the results show high splitting ratio for single-mode and multi-mode operation with low losses. Based on the simulations, a 3D beam splitter was designed and realized using direct laser writing (DLW) process with adaptation to coupling to standard single-mode fiber. With respect to the technological limits, the multi-mode splitter having core of (4 × 4) μm 2 was designed and fabricated together with supporting stable mechanical construction. Splitting properties were investigated by intensity monitoring of splitter outputs using optical microscopy and near-field scanning optical microscopy. In the development phase, the optical performance of fabricated beam splitter was examined by splitting of short visible wavelengths using red light emitting diode. Finally, the splitting of 1550 nm laser light was studied in detail by near-field measurements and compared with the simulated results. The nearly single-mode operation was observed and the shape of propagating mode and mode field diameter was well recognized.
Synthetic polymers, such as polyamide (PA), inherently possess a moderate number of surface functionalities compared to natural polymers, which negatively impacts the uniformity of metallic coatings obtained through wet-chemical methods like electroless plating. The paper presents the use of a siloxane interlayer formed from the condensation of the hydrolyzed 3-triethoxysilylpropyl succinic anhydride (TESPSA) precursor as a strategy to modify the surface properties of polyamide 6.6 (PA66) fabrics and improve the uniformity of the copper surface coating. The application of the siloxane intermediate coating demonstrates a significant improvement in electrical conductivity, up to 20 times higher than fabrics without the interlayer. The morphology of the coatings was investigated using scanning electron (SEM) and laser confocal scanning microscopy (LSM). In addition, dye adsorption, flexural rigidity, air permeability and contact angle measurements were conducted to monitor the change in the PA66 properties after the siloxane functionalization.
An electrochemical study with three redox substances on a carbon based nanogap electrode array
(2020)
Arrayed Waveguide Grating (AWG) is a passive optical component, which have found applications in a wide range of photonic applications including telecommunications and medicine. Silica-on-Silicon (SoS) based AWGs use a low refractive-index contrast between the core (waveguide) and the cladding which leads to some significant advantages such as low propagation losses and low fiber coupling losses between the AWG waveguides and the fibres. Therefore, they are an attractive DWDM solution offering higher channel count technology and good performance characteristics compared to other methods. However, the very low refractive-index contrast means the bending radius of the waveguides needs to be very large (on the order of several millimeters) and may not fall below a particular critical value to suppress bending losses. As a result, silica-based waveguide devices usually have a very large size that limits the integration density of SiO2-based photonic integrated devices. High-index contrast AWGs (such as silicon, silicon nitride or polymer-based waveguide devices) feature much smaller waveguide size compared to low index contrast AWGs. Such compact devices can easily be implemented on a chip and have already found applications in emerging applications such as optical sensors, devices for DNA diagnostics and optical spectrometers for infrared spectroscopy.In this work, we present the design, simulation, technological verification and applications of both, the low-index contrast and high-index contrast AWGs. For telecommunication applications AWG-MUX/Demux with up to 128-channels will be presented. For medical applications the AWG-spectrometer with up to 512-channels will be presented.This work was carried out in the framework of the projects: ADOPT No. SK-AT-20-0012, NOVASiN No. SK-AT-20-0017 and AUTOPIC No. APVV-17-0662 from Slovak research and development agency of Ministry of Education, Science, Research and Sport of the Slovak Republic and No. SK 07/2021 and SK 08/2021 from Austrian Agency for International Cooperation in Education and Research (OeAD-GmbH); and project PASTEL, no. 2020-10-15-001, funded by SAIA.
Beyond the Four-Level Model: Dark and Hot States in Quantum Dots Degrade Photonic Entanglement
(2023)
Entangled photon pairs are essential for a multitude of quantum photonic applications. To date, the best performing solid-state quantum emitters of entangled photons are semiconductor quantum dots operated around liquid-helium temperatures. To favor the widespread deployment of these sources, it is important to explore and understand their behavior at temperatures accessible with compact Stirling coolers. Here we study the polarization entanglement among photon pairs from the biexciton–exciton cascade in GaAs quantum dots at temperatures up to ∼65 K. We observe entanglement degradation accompanied by changes in decay dynamics, which we ascribe to thermal population and depopulation of hot and dark states in addition to the four levels relevant for photon pair generation. Detailed calculations considering the presence and characteristics of the additional states and phonon-assisted transitions support the interpretation. We expect these results to guide the optimization of quantum dots as sources of highly entangled photons at elevated temperatures.
The production of liquid-gas dispersions places high demands on the process technology, which requires knowledge of the bubble formation mechanisms, as well as the phase parameters of the media combinations used. To obtain the bubble sizes introduced to a flow not knowing the phase parameters, different process parameters are investigated. Their quality and applicability are evaluated. The results obtained make it possible to simplify long design processes of dispersion processes in manufacturing plants and to ensure the product quality of the products manufactured, by reducing waste.
In this study, we carried out the structural and thermal characterization of a medical-grade poly (lactide) (PLA) by SEC, TGA, DSC, NMR, ICP-MS and Py-GC/MS. Moreover, we investigated the laser-induced degradation occurring when ultrashort laser pulses (ULP) were employed to cut extremely thin polymer films prepared by solvent-casting. ULP polymer cutting technology is an interesting manufacturing process for its advantages in potential medical applications. In fact, heat transmission to the region surrounding the cuts is limited, so that the incisions are precise and the effects on the regions around them are small. In this way, the need for post-processing is reduced and ULP cutting becomes interesting for industrial applications. However, degradation induced by ULP may occur and compromise the properties of the polymer samples. To investigate this possibility, portions of PLA films, ultrashort laser cut (ULC) and uncut, were analysed by SEC, DSC, NMR and FTIR. Furthermore, PLA oligomers were studied by ESI-MS. Both SEC and NMR showed a decrease in the molecular weight. FTIR, ESI-MS and NMR spectra revealed the presence of olefin end groups originated from a \beta-H transfer mechanism, induced by heat and/or light (Norrish II mechanism). Additionally, the inspection of the ESI mass spectra highlighted the cleavage of ester bonds related to the Norrish I type mechanism, undetected by the other techniques.
Combining parallel pattern generation of electrohydrodynamic lithography with serial addressing
(2018)
In this paper, the design of three-dimensional configuration of Y-branch splitter is compared with Multimode Interference splitter. Both splitters use the IP-Dip polymer as a standard material for 3D laser lithography. The optical properties of the splitters for both approaches are discussed and compared.
Compression of ultrashort laser pulses via gated multiphoton intrapulse interference phase scans
(2014)
Recently the use of microRNAs (miRNAs) as biomarkers for a multitude of diseases has gained substantial significance for clinical as well as point-of-care diagnostics. Amongst other challenges, however, it holds the central requirement that the concentration of a given miRNA must be evaluated within the context of other factors in order to unambiguously diagnose one specific disease. In terms of the development of diagnostic methods and devices, this implies an inevitable demand for multiplexing in order to be able to gauge the abundance of several components of interest in a patient’s sample in parallel. In this study, we design and implement different multiplexed versions of our electrochemical microfluidic biosensor by dividing its channel into subsections, creating four novel chip designs for the amplification-free and simultaneous quantification of up to eight miRNAs on the CRISPR-Biosensor X (‘X’ highlighting the multiplexing aspect of the device). We then use a one-step model assay followed by amperometric readout in combination with a 2-minute-stop-flow-protocol to explore the fluidic and mechanical characteristics and limitations of the different versions of the device. The sensor showing the best performance, is subsequently used for the Cas13a-powered proof-of-concept measurement of two miRNAs (miRNA-19b and miRNA-20a) from the miRNA-17∼92 cluster, which is dysregulated in the blood of pediatric medulloblastoma patients. Quantification of the latter, alongside simultaneous negative control measurements are accomplished on the same device. We thereby confirm the applicability of our platform to the challenge of amplification-free, parallel detection of multiple nucleic acids.
This paper presents a project developed at the K.S.Rangasamy College of Technology (Tamilnadu,India) aimed at designing, implementing, and testing an autonomous multipurpose vehicle with safe, efficient, and economic operation. This autonomous vehicle moves through the crop lines of a Agricultural land and performs tasks that are tedious and/or hazardous to the farmers. First, it has been equipped for spraying, but other configurations have also been designed, such as: a seeding ,plug platform to reach the top part of the plants to perform different tasks (pruning, harvesting, etc.), and a trailer to transport the fruits, plants, and crop waste.
The paper deals with designing and numerical modelling a 2 x 2 optical switch for photonic integrated circuits based on 2 x 2 MMI elements and phase modulators. The 2 x 2 optical switch was modelled in the RsoftCAD with the simulation tool BeamPROP. The 2 x 2 optical switch is a common element for creating more complex 1 x N or N x N optical switches in all-optical signal processing.
Design and optimization of 1x2N Y-branch optical splitters for telecommunication applications
(2020)
This paper presents the design and optimization of 1x2N Y-branch optical splitters for telecom applications. A waveguide channel profile, used in the splitter design, is based on a standard silica-on-silicon material platform. Except for the lengths of the used Y-branches, design parameters such as port pitch between the waveguides and simulation parameters for all splitters were considered fixed. For every Y-branch splitter, insertion loss, non-uniformity, and background crosstalk are calculated. According to the minimum insertion loss and minimum non-uniformity, the optimum length for each Y-branch is determined. Finally, the individual Y-branches are cascade joined to design various Y-branch optical splitters, from 1x2 to 1x64.
This paper aims to study the design, simulation, and optimization of low-loss Y-branch passive optical splitters up to 64 output ports for telecommunication applications. For a waveguide channel profile, the standard material silica-on-silicon is used. The Y-splitters are designed and simulated at telecommunication operating wavelength, λ = 1550 nm. Except for the lengths of the used Y-branches, and a core size of the waveguides, design parameters such as port pitch between the waveguides and simulation parameters for all splitters are considered fixed. The simulation results are analyzed to determine the optimum length of the splitters and the optimum core size. Based on this optimization the total length of the highest designed 1×64 Y-branch splitter was reduced by 41.14 % for a waveguide core (5×5) μm2 compared to the length of splitter with a standard (6×6) μm2 core size.
We present design of planar 16-channel, 100-GHz multi-mode polymer-based AWG. This AWG was designed for central wavelength of 1550 nm applying AWG-Parameters tool. The AWG structure was created and simulated in the commercial photonic tool PHASAR from Optiwave. Achieved transmission characteristics were evaluated by AWG-Analyzer tool. For the design, multi-mode waveguides having a cross-section of (4x4) µm2 were used. The simulated results show strong worsening of the transmission characteristics in comparison when using single-mode waveguides. Nevertheless, the transmitting channels are clearly separated. The reason for using thicker multi-mode waveguides in the design is possibility to fabricate the AWG structure on polymer basis using direct laser writing lithography.
Over the last years, polymers have gained great attention as substrate material, because of the possibility to produce low-cost sensors in a high-throughput manner or for rapid prototyping and the wide variety of polymeric materials available with different features (like transparency, flexibility, stretchability, etc.). For almost all biosensing applications, the interaction between biomolecules (for example, antibodies, proteins or enzymes) and the employed substrate surface is highly important. In order to realize an effective biomolecule immobilization on polymers, different surface activation techniques, including chemical and physical methods, exist. Among them, plasma treatment offers an easy, fast and effective activation of the surfaces by micro/nanotexturing and generating functional groups (including carboxylic acids, amines, esters, aldehydes or hydroxyl groups). Hence, here we present a systematic and comprehensive plasma activation study of various polymeric surfaces by optimizing different parameters, including power, time, substrate temperature and gas composition. Thereby, the highest immobilization efficiency along with a homogenous biomolecule distribution is achieved with a 5-min plasma treatment under a gas composition of 50% oxygen and nitrogen, at a power of 1000 W and a substrate temperature of 80 C. These results are also confirmed by different surface characterization methods, including SEM, XPS and contact angle measurements.
In previous studies of linear rotary systems with active magnetic bearings, parametric excitation was introduced as an open-loop control strategy. The parametric excitation was realized by a periodic, in-phase variation of the bearing stiffness. At the difference between two of the eigenfrequencies of the system, a stabilizing effect, called anti-resonance, was found numerically and validated in experiments. In this work, preliminary results of further exploration of the parametric excitation are shared. A Jeffcott rotor with two active magnetic bearings and a disk is investigated. Using Floquet theory, a deeper insight into the dynamic behavior of the system is obtained. Aiming at a further increase of stability, a phase difference between excitation terms is introduced.
Modern portable electronic devices have seen component heat load increasing, while the space available for heat dissipation has decreased. This requires the thermal management system to be optimized to attain the high performance heat sink. Heat sinks plays a major role for dissipating heat in electronic devices. Phase change material (PCM) is used to enhance the heat dissipation in heat sink. This paper reports the results of an experimental investigation of the performance of Pin fin heat sinks filled with phase change materials for thermal management of electronic devices. The experimental set ups are prepared with the graphical programming language with Lab VIEW (Laboratory Virtual Instruments for Engineering Workbench. Three different types of Pin fin Heat sink with and without PCM are investigated based on different operational timings and the temperature is acquired with the help of Data Acquisition Card (DAQ). The results indicated that the inclusion of the PCM could stabilize the temperature for a longer period and reduce the heating rates and peak temperatures of heat sink with increasing the number of fins can enhance the thermal performance of electronic devices.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2023)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2022)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.