Refine
Year of publication
Document Type
- Article (369) (remove)
Institute
- Wirtschaft (110)
- Forschungszentrum Mikrotechnik (84)
- Forschungszentrum Business Informatics (59)
- Department of Computer Science (Ende 2021 aufgelöst) (54)
- Forschungszentrum Energie (44)
- Soziales und Gesundheit (36)
- Didaktik (21)
- Forschungsgruppe Empirische Sozialwissenschaften (19)
- Forschungszentrum Nutzerzentrierte Technologien (7)
- Gestaltung (3)
Language
- English (237)
- German (130)
- Multiple languages (2)
Keywords
- Laser ablation (8)
- Entscheidung (6)
- Volatile organic compounds (5)
- Ausscheidung (4)
- Evolution strategy (4)
- Y-branch splitter (4)
- Desalination (3)
- Evolution strategies (3)
- Fragmentation patterns (3)
- Mathematical model (3)
Zeigen, nicht erklären!
(2020)
Medien sind während der Covid-Pandemie in besonderem Maße gefordert, komplexe Sachverhalte, wie Inzidenzen und exponentielles Wachstum einfach zu erklären. Informationsgrafiken sind dazu bestens geeignet, erfordern allerdings hohe Kompetenz in der Erstellung. Dieser Artikel plädiert für die Einführung eines eigenen journalistischen Genres, nämlich des visuellen Journalismus.
X-ray micro tomography of three-dimensional embroidered current collectors for lithium-ion batteries
(2016)
Wirtschaftsethik
(2020)
Wirtschaftliche und ethische Handlungen sind zugleich realisierbar, wenn zwischen einer einrahmenden Wirtschaftsordnung (Spielregeln) und einzelnen Handlungen (Spielzügen) unterschieden wird. Das wirtschaftliche Tun und Unterlassen wird dann in den Spielzügen und die Ethik über die Spielregeln realisierbar. Die Gültigkeit einer Wirtschaftsordnung setzt einen allgemeinen Konsens über die Spielregeln und die Durchsetzungsinstanzen (z. B: Justiz oder Kartellamt) voraus. Dann regelt sie den Wettbewerb und nötigt Anbieter, sich an den Interessen der Nachfrager zu orientieren und dabei auf einen effizienten Ressourceneinsatz zu achten. So erfolgt das individuelle Handeln der Marktteilnehmer in der einrahmenden Wirtschaftsordnung mit den darin befindlichen Anreizen, daher spricht man von einer Anreizethik. Mit ihr werden wirtschaftliche und ethische Handlungen zugleich realisierbar.
In this paper, low-loss Y-branch splitters up to 128 splitting ratio are designed, simulated, and optimized by using 2D beam propagation method in OptiBPM tool by Optiwave. For an optical waveguide, a silica-on-silicon material platform is used. The splitters were designed as a planar structure for a telecommunication operating wavelength of 1.55 m. According to the minimum insertion loss and minimum non-uniformity, the optimum length for each Y-branch is determined. The influence of the pre-defined S-Bend waveguide shapes (Arc, Cosine, Sine) and of the waveguide core size reduction on the splitter performance has been also studied. The obtained simulation results of all designed splitters with different S-Bend shape waveguides together with the different waveguide core sizes are discussed and compared with each other.
Greater specific energy densities in lithium-ion batteries can be achieved by using three-dimensional (3D) porous current collectors, which allow for greater areal mass loadings of the electroactive material. In this paper, we present the use of embroidered current collectors for the preparation of thick, pouch-type Li-ion batteries. Experiments were performed on LiFePO 4 (LFP) water-based slurries using styrene-butadiene rubber (SBR) as binder and sodium carboxymethyl cellulose (CMC) as thickener, and formulations of different rheological characteristics were investigated. The electrochemical performance (cyclic voltammetry, rate capability) and morphological characteristics of the LFP half-pouch cells (X-ray micro computed tomography and scanning electron microscopy) were compared between the formulations. An optimum electrode formulation was identified, and a mechanism is proposed to explain differences between the formulations. With the optimum electrode formulation, 350 µm casted electrodes with high mechanical stability were achieved. Electrodes exhibited 4–6 times greater areal mass loadings (4–6 mAh cm −2 ) and 50% greater electroactive material weight than with foils. In tests of half- and full-pouch embroidered cells, a 50% capacity utilization at 1C-rate and 11% at 2C-rate were observed, with a full recovery at C/5-rate. The cycling stability was also maintained over 55 cycles.
Was Kennzahlen aussagen
(2021)
Was ist als Ergebnis der Operation 1 : 2 als „korrekt“ anzuerkennen? In der Menge der natürlichen Zahlen N ist 0 korrekt, in der Menge der rationalen Zahlen Q ist 0,5 richtig. Was „wahr“ ist, hängt also von den Ermittlungs- und Berechnungsgrundlagen ab. Das übersehen viele Führungskräfte beim Umgang mit Kennzahlen genau so, wie die Bedeutung ihrer kommunikativen Kompetenzen.
If left uncontrolled, electric vehicle charging poses severe challenges to distribution grid operation. Resulting issues are expected to be mitigated by charging control. In particular, voltage-based charging control, by relying only on the local measurements of voltage at the point of connection, provides an autonomous communication-free solution. The controller, attached to the charging equipment, compares the measured voltage to a reference voltage and adapts the charging power using a droop control characteristic. We present a systematic study of the voltage-based droop control method for electric vehicles to establish the usability of the method for all the currently available residential electric vehicle charging possibilities considering a wide range of electric vehicle penetrations. Voltage limits are evaluated according to the international standard EN50160, using long-term load flow simulations based on a real distribution grid topology and real load profiles. The results achieved show that the voltage-based droop controller is able to mitigate the under voltage problems completely in distribution grids in cases either deploying low charging power levels or exhibiting low penetration rates. For high charging rates and high penetrations, the control mechanism improves the overall voltage profile, but it does not remedy the under voltage problems completely. The evaluation also shows the controller’s ability to reduce the peak power at the transformer and indicates the impact it has on users due to the reduction in the average charging rates. The outcomes of the paper provide the distribution grid operators an insight on the voltage-based droop control mechanism for the future grid planning and investments.
Verstehen und Information
(2013)
We have investigated the ablation behaviour of single crystal SrTiO3 <100> with focus on the influence of the pulse duration at a wavelength of 248 nm. The experiments were performed with KrF-excimer lasers with pulse durations of 34 ns and 500 fs, respectively. Femtosecond-ablation turns out to be more efficient by one order of magnitude and to eliminate the known problem of cracking of SrTiO3 during laser machining with longer pulses. In addition, the cavities ablated with femtosecond pulses display a smoother surface with no indication of melting and well-defined, sharp edges. These effects can be explained by the reduced thermal shock effect on the material by using ultrashort pulses.
Adult muscle carnitine palmitoyltransferase (CPT) II deficiency is a rare autosomal recessive disorder of long-chain fatty acid metabolism. It is typically associated with recurrent episodes of exercise-induced rhabdomyolysis and myoglobinuria, in most cases caused by a c.338C > T mutation in the CPT2 gene. Here we present the pedigree of one of the largest family studies of CPT II deficiency caused by the c.338C > T mutation, documented so far. The pedigree comprises 24 blood relatives
of the index patient, a 32 year old female with genetically proven CPT II deficiency. In total, the mutation was detected in 20 family members, among them five homozygotes and 15 heterozygotes. Among all homozygotes, first symptoms of CPT II deficiency occurred during childhood. Additionally, two already deceased relatives of the index patient were carriers of at least one copy of the genetic variant, revealing a remarkably high prevalence of the c.338C > T mutation within the tested family. Beside the index patient, only one individual had been diagnosed with CPT II deficiency prior to this study and three cases of CPT II deficiency were newly detected by this family study, pointing
to a general underdiagnosis of the disease. Therefore, this study emphasizes the need to raise awareness of CPT II deficiency for correct diagnosis and accurate management of the disease.
Zusammenfassung: Eine umfassende Literaturrecherche (Comprehensive Literature Search, CLS) bezeichnet eine umfangreiche und aufwändige Recherche mit dem Ziel, möglichst alle Studien zur Beantwortung einer zugrundeliegenden Forschungsfrage im Rahmen einer systematischen Übersichtsarbeit zu identifizieren. Konkrete Empfehlungen oder eine Definition des Begriffs CLS gibt es jedoch nicht. Der vorliegende Beitrag führt in eine Rahmung der CLS ein, stellt die damit einhergehenden Herausforderungen dar und weist auf methodische Implikationen sowie mögliche zukünftige Forschungsbereiche hin.
In recent years, ultrashort pulsed lasers have increased their applicability for industrial requirements, as reliable femtosecond and picosecond laser sources with high output power are available on the market. Compared to conventional laser sources, high quality processing of a large number of material classes with different mechanical and optical properties is possible. In the field of laser cutting, these properties enable the cutting of multilayer substrates with changing material properties. In this work, the femtosecond laser cutting of phosphor sheets is demonstrated. The substrate contains a 230 micrometer thick silicone layer filled with phosphor, which is embedded between two glass plates. Due to the softness and thermal sensitivity of the silicone layer in combination with the hard and brittle dielectric material, the separation of such a material combination is challenging for both mechanical separation processes and cutting with conventional laser sources. In our work, we show that the femtosecond laser is suitable to cut the substrate with a high cutting edge quality. In addition to the experimental results of the laser dicing process, we present a universal model that allows predicting the final cutting edge geometry of a multilayer substrate.
Transparent laser-structured glasses with superhydrophilic properties for anti-fogging applications
(2019)
Ultrashort pulse laser structuring enables direct modification of glass surfaces to generate superhydrophilic properties for anti-fogging applications. This approach makes coatings dispensable and the generated surfaces remain thermally, mechanically, and chemically resistant. However, the laser-generated structures usually cause scattering, which decreases transmission and may disturb the vision through the modified glass in the dry state. The aim of this study was to find a laser-processing strategy to achieve superhydrophilic, anti-fogging properties on glass surfaces with maximum transmission and minimal visual perception of the generated structure. For this purpose, we used an ultrashort-pulsed laser to generate periodic patterns of rippled circles or rough holes with varying pitch. The water contact angle and transmission of the structured glasses were measured as a function of the structured area. It was found that a periodic pattern of holes, which covers less than 1% of the surface, is already sufficient to reach the superhydrophilic state (contact angle < 5°) and provides nearly the same transmission as pristine glass. Pictures of objects imaged through dry, structured glasses, which were placed close to the lens or object, showed in both cases only a minimal decrease of contrast. If this minor drawback can be accepted, this direct laser structuring approach could be an interesting alternative to coating-based techniques and leaves even room to apply additional coatings for the fabrication of multi-functional special glasses.
In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.