Refine
Year of publication
- 2019 (94) (remove)
Document Type
- Conference Proceeding (48)
- Article (23)
- Part of a Book (12)
- Book (7)
- Doctoral Thesis (1)
- Other (1)
- Periodical (1)
- Part of Periodical (1)
Institute
- Forschungszentrum Mikrotechnik (28)
- Forschungszentrum Business Informatics (17)
- Wirtschaft (13)
- Soziales & Gesundheit (12)
- Technik | Engineering & Technology (9)
- Forschungszentrum Energie (8)
- Forschungszentrum Human Centred Technologies (8)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (6)
- Didaktik (mit 31.03.2021 aufgelöst; Integration ins TELL Center) (5)
- Department of Engineering (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (3)
Is part of the Bibliography
- yes (94) (remove)
Keywords
Selbst sicher sein
(2019)
Transparent laser-structured glasses with superhydrophilic properties for anti-fogging applications
(2019)
Ultrashort pulse laser structuring enables direct modification of glass surfaces to generate superhydrophilic properties for anti-fogging applications. This approach makes coatings dispensable and the generated surfaces remain thermally, mechanically, and chemically resistant. However, the laser-generated structures usually cause scattering, which decreases transmission and may disturb the vision through the modified glass in the dry state. The aim of this study was to find a laser-processing strategy to achieve superhydrophilic, anti-fogging properties on glass surfaces with maximum transmission and minimal visual perception of the generated structure. For this purpose, we used an ultrashort-pulsed laser to generate periodic patterns of rippled circles or rough holes with varying pitch. The water contact angle and transmission of the structured glasses were measured as a function of the structured area. It was found that a periodic pattern of holes, which covers less than 1% of the surface, is already sufficient to reach the superhydrophilic state (contact angle < 5°) and provides nearly the same transmission as pristine glass. Pictures of objects imaged through dry, structured glasses, which were placed close to the lens or object, showed in both cases only a minimal decrease of contrast. If this minor drawback can be accepted, this direct laser structuring approach could be an interesting alternative to coating-based techniques and leaves even room to apply additional coatings for the fabrication of multi-functional special glasses.
In this study, we carried out the structural and thermal characterization of a medical-grade poly (lactide) (PLA) by SEC, TGA, DSC, NMR, ICP-MS and Py-GC/MS. Moreover, we investigated the laser-induced degradation occurring when ultrashort laser pulses (ULP) were employed to cut extremely thin polymer films prepared by solvent-casting. ULP polymer cutting technology is an interesting manufacturing process for its advantages in potential medical applications. In fact, heat transmission to the region surrounding the cuts is limited, so that the incisions are precise and the effects on the regions around them are small. In this way, the need for post-processing is reduced and ULP cutting becomes interesting for industrial applications. However, degradation induced by ULP may occur and compromise the properties of the polymer samples. To investigate this possibility, portions of PLA films, ultrashort laser cut (ULC) and uncut, were analysed by SEC, DSC, NMR and FTIR. Furthermore, PLA oligomers were studied by ESI-MS. Both SEC and NMR showed a decrease in the molecular weight. FTIR, ESI-MS and NMR spectra revealed the presence of olefin end groups originated from a \beta-H transfer mechanism, induced by heat and/or light (Norrish II mechanism). Additionally, the inspection of the ESI mass spectra highlighted the cleavage of ester bonds related to the Norrish I type mechanism, undetected by the other techniques.
Progress in integrated photonics enables development of integrated photonics circuits with new unique properties, circuits of the future, and overcomes current limits in information and communication technologies. The packaging of photonic integrated circuits is necessary for taking them out of research laboratories into real implementation in the information and communication technology applications.
Telecom optical fibers are still being the best transmission medium of digital data and analogue signals for long distance applications. The effective coupling of optical radiation between telecom optical fiber with ten microns core dimension and photonic integrated circuits optical waveguides with submicron dimensions are necessary. To address these challenges, we present our concept of photonics integrated circuit packaging with radio frequency, direct current and fiber array ports with automated active alignment system.
SiN is a suitable material for fabricating of photonic integrated circuits with middle refractive index contrast for the visible and near infrared spectral region with ultra-low propagation losses. The paper deals with the design and simulation of fiber to SiN chip butt coupler with single step fabrication process without thickness tapering. Coupler is designed for 850 nm band for coupling between strip 0.25 μm × 1.00 μm waveguide and Nufern's 780-OCT single mode optical fiber with core diameter 4.4 μm. The coupling losses simulation results of the two simulation methods finite-difference beam propagation techniques and eigenmode expansion method are compared.
A multi-recombinative active matrix adaptation evolution strategy for constrained optimization
(2019)
Varying mindsets in Design Thinking. Why they change during the process and how to nudge them
(2019)
Stress testing is part of today’s bank risk management and often required by the governing regulatory authority. Performing such a stress test with stress scenarios derived from a distribution, instead of pre-defined expert scenarios, results in a systematic approach in which new severe scenarios can be discovered. The required scenario distribution is obtained from historical time series via a Vector-Autoregressive time series model. The worst-case search, i.e. finding the scenario yielding the most severe situation for the bank, can be stated as an optimization problem. The problem itself is a constrained optimization problem in a high-dimensional search space. The constraints are the box constraints on the scenario variables and the plausibility of a scenario.
The latter is expressed by an elliptic constraint. As the evaluation of the stress scenarios is performed with a simulation tool, the optimization problem can be seen as black-box optimization problem. Evolution Strategy, a well-known optimizer for black-box problems, is applied here. The necessary adaptations to the algorithm are explained and a set of different algorithm design choices are investigated. It is shown that a simple box constraint handling method, i.e. setting variables which violate a box constraint to the respective boundary of the feasible domain, in combination with a repair of implausible scenarios provides good results.
In engineering design, optimization methods are frequently used to improve the initial design of a product. However, the selection of an appropriate method is challenging since many
methods exist, especially for the case of simulation-based optimization. This paper proposes a systematic procedure to support this selection process. Building upon quality function deployment, end-user and design use case requirements can be systematically taken into account via a decision
matrix. The design and construction of the decision matrix are explained in detail. The proposed
procedure is validated by two engineering optimization problems arising within the design of box-type boom cranes. For each problem, the problem statement and the respectively applied optimization methods are explained in detail. The results obtained by optimization validate the use
of optimization approaches within the design process. The application of the decision matrix shows the successful incorporation of customer requirements to the algorithm selection.
Zusammenfassung: Eine umfassende Literaturrecherche (Comprehensive Literature Search, CLS) bezeichnet eine umfangreiche und aufwändige Recherche mit dem Ziel, möglichst alle Studien zur Beantwortung einer zugrundeliegenden Forschungsfrage im Rahmen einer systematischen Übersichtsarbeit zu identifizieren. Konkrete Empfehlungen oder eine Definition des Begriffs CLS gibt es jedoch nicht. Der vorliegende Beitrag führt in eine Rahmung der CLS ein, stellt die damit einhergehenden Herausforderungen dar und weist auf methodische Implikationen sowie mögliche zukünftige Forschungsbereiche hin.
Adult muscle carnitine palmitoyltransferase (CPT) II deficiency is a rare autosomal recessive disorder of long-chain fatty acid metabolism. It is typically associated with recurrent episodes of exercise-induced rhabdomyolysis and myoglobinuria, in most cases caused by a c.338C > T mutation in the CPT2 gene. Here we present the pedigree of one of the largest family studies of CPT II deficiency caused by the c.338C > T mutation, documented so far. The pedigree comprises 24 blood relatives
of the index patient, a 32 year old female with genetically proven CPT II deficiency. In total, the mutation was detected in 20 family members, among them five homozygotes and 15 heterozygotes. Among all homozygotes, first symptoms of CPT II deficiency occurred during childhood. Additionally, two already deceased relatives of the index patient were carriers of at least one copy of the genetic variant, revealing a remarkably high prevalence of the c.338C > T mutation within the tested family. Beside the index patient, only one individual had been diagnosed with CPT II deficiency prior to this study and three cases of CPT II deficiency were newly detected by this family study, pointing
to a general underdiagnosis of the disease. Therefore, this study emphasizes the need to raise awareness of CPT II deficiency for correct diagnosis and accurate management of the disease.
Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a cohort of 23 volunteers using proton transfer reaction mass spectrometry. The breathing maneuvers embraced distinct depths of respiration, exhalation manners, size of the mouth opening and different sampling distances. Two inhalation modes (normal, relaxed breathing and deep breathing) and two exhalation manners (via smaller and wider lips opening) forming four sampling scenarios were selected. A sampling distance of approximately 2 cm was found to be a reasonable trade-off between sample dilution and requirement of no physical contact of the subject with the analyzer. All four scenarios exhibited comparable measurement reproducibility spread of around 10%. For normal, relaxed inspiration both dead-space and end-tidal phases of exhalation lasted approximately 1.5 s for both expiration protocols. Deep inhalation prolongs the end-tidal phase to about 3 s in the case of blowing via a small lips opening, and by 50% when the air is exhaled via a wide one. In conclusion, non-contact breath sampling can be considered as a promising alternative to the existing breath sampling methods, being relatively close to natural spontaneous breathing.
Optical splitters are passive optical components, which have found applications in a wide range of telecom, sensing, medical and many other scientific areas.
Low-index contrast optical splitters (Silica-on-Silicon (SoS) based waveguide devices) feature many advantages such as low fiber coupling losses and low propagation losses. They are considered an attractive DWDM solution in the telecommunication for all optical signal processing in optical communication systems. Nowadays the steadily increasing data volume in communication networks is driven by a rapid proliferation of home-based and business computers, storage capacities, processing capabilities and the extensive availability of Internet. The challenge is to transfer high data volumes in short periods of time over high distances as lossless as possible. The task of the optical splitters in Fiber-to-the-x (FTTx) network is to split one optical signal in many identical signals bringing for example the same TV signal in different households. Of course, the more buildings can be served by one optical splitter the lower are the installation costs.
High-index contrast optical splitters (such as silicon, silicon nitride or polymer based waveguide devices) feature much smaller waveguide size compared to low index contrast splitters. Such compact devices can easily be implemented on-chip and have already been used in the development of optical sensors, devices for DNA diagnostics and for infrared spectroscopy.
We will present the latest achievements in the design of two mostly used optical splitters (MMI and Y-branch) and discuss their advantages and disadvantages. Finally, some applications of the splitters developed in the frame of various projects will be presented.
This work was carried out in the framework of the project PHOCOP (no. SK-AT-2017-0013) and NAMOPRISIN (no. SK-AT-2017-0005) from the Slovak research and development agency of the Ministry of Education, Science, Research and Sport of the Slovak Republic and SK 16/2018 and 15/2018 from OeAD-GmbH.
Interstitial photodynamic therapy (iPDT) treats malignant brain cancer cells by irradiation with low power laser light. The light is guided into the human body by diffuse emitting fibers. This study targets the light distribution of optical diffusers within the brain tissue. It was shown, that by submerging an optical diffuser into human brain phantom, its radiation profile measured in air converges towards a Gaussian distribution with increasing phantom depth. A camera method using digital averaging filters as well as an integrating sphere setup, both, smoothing the diffuser radiation profile were applied onto the evaluated diffuser.
Investigations on mechanical stability of laser machined optical fibre tips for medical application
(2019)
Light delivery is a challenging task, when it comes to medical applications. The light is guided through optical fibers from the light source towards the treatment region. In case of interstitial light application, the light has to be decoupled from the fibre and spread to the surrounding tissue. To reach larger tissue volumes, this can be either obtained by adding a scattering volume to the tip of the fibre, or by directly modifying the optical fibre itself in order to break the total reflection within the fibre core. Such modifications can be either on the fibre surface itself or internally in the fibre core. One approach to obtain the fibre structuring could be laser induced surface roughening using an ultrafast laser source. While using volume scattering as diffusor at the fibre tip is currently the gold standard for non-thermal applications (< 0.3W/cm), the decoupling of high power laser intensities for thermal treatment options is still challenging. Structuring the fibre core itself usually is related with a loss of mechanical stability. As fibre breakage and potential loss within the human body can have serious consequences, the mechanical stability is one of the quality criterion in diffuser manufacturing. Therefore, investigations about the mechanical stability of laser manufactured optical fibre diffusers are needed.
In order to evaluate the mechanical stability, a 4-point as well as a 2-point breaking test were developed. Different fibre diffusers, based on volume or surface scattering, were manufactured using fs-laser ablation techniques and its breaking strengths were investigated.
It could be shown that for surface fibre modifications, the mechanical stability reduces with increasing defect depth. The stability significantly drops when the laser ablation was performed in the thermal energy range. Volume scattering modified fibres only showed a slight reduction in stability compared to un-machined fibres.
In conclusion, internal fibre modification seems to be the most promising method to establish optical fibre diffusers, which are capable of several watts of emission power, while preserving its mechanical strength.
Abstract: ams AG is a leading provider of sensing solutions developing semiconductor sensors in a wide variety of fields, with optical sensing as one of the key competences. Since integrated photonics is a promising technology for new sensor systems, ams AG has been developing processes for fully integrated CMOS-compatible photonic components based on Si3N4. This talk will provide an overview on the processing of basic photonic building blocks and their optical properties and performance. We will also give examples for applications in the fields of optical coherence tomography and opto-chemical gas sensing. In the 1980s photonics started its way for common use in telecommunication technology, using optical fiber technologies. In recent years, also a variety of photonic sensors has been proposed and developed. One of the major drawbacks of most of these photonic devices has been the lack of integration into existing (semiconductor) production processes, so far. This integration is feasible using SiN material systems to process monolithically integrated CMOS-compatible photonic sensors in the visible and near-infrared spectrum. We will present the basic processing steps for the SiN photonic technology, the development of some critical processing steps such as SiN deposition and SiN etching as well as several photonic components (waveguides, splitters, etc.) with their optical properties. One of the applications presented relates to optical coherence tomography (OCT), a fast growing imaging technique in ophthalmology. Drawbacks of existing OCT systems are their high costs as well as their bulkiness, which prevents a wider spread use of OCT systems.
One way to overcome both cost and size issues is to integrate optical and electrical components on a single chip.
Part of this work was carried out in the framework of the projects COHESION (funded by the Austrian Research Promotion Agency (FFG), no. 848588), OCTCHIP (funded by the EU’ Horizon 2020 research and innovation programme, no. 688173), and COLODOR (M-ERA.NET transnational Call 2015, funded by the Austrian Research Promotion Agency (FFG), no.854066, and the Bundesministerium für Bildung und Forschung, Germany).
Analysis of the (μ/μI,λ)-CSA-ES with repair by projection applied to a conically constrained problem
(2019)
Verstärkt der Handel mit Agrar-Derivaten die Preisschwankungen von Agrar-Produkten? In der politischen Diskussion wird diese These oft als Grund für eine strenge Reglementierung des Handels mit Agrar-Derivaten angeführt. Hier diskutiere ich die Voraussetzungen, auf denen verschiedene Argumente für diese These beruhen. Eine zentrale Rolle dabei spielen die Begriffe von Gleichgewicht und Selbstreferenz. Diese Begriffe spielen in der Logik und der Physik eine wichtige Rolle, haben aber in der Ökonomie erstaunliche Konsequenzen.
In dieser Arbeit wird Supervised Learning verwendet, um die Zuverlässigkeit von Schweißverbindungen zu evaluieren.
Um die Schweißqualität zu bestimmen, wurden End of Life Tests durchgeführt. Für die statistische Auswertung und Vorhersage der zu erwartenden Lebensdauer, wurden die Daten basierend auf einer logarithmischen Normalverteilung und mit einer multivariablen linearen Regression modelliert. Um die signifikanten Einflussfaktoren zu identifizieren, wurde eine schrittweise Regression genutzt. Die Ergebnisse zeigen, dass das entwickelte Modell die Zuverlässigkeit und Lebensdauer der Schweißverbindung akkurat abbildet und präzise Vorhersagen liefern kann.
We report resent results on the fabrication and characterization of carbon nanogap interdigitated electrode arrays (IDAs) for biosensor applications based on redox cycling. The electrochemical results of the carbon electrodes are compared to our fabricated gold electrodes with similar nanogap distances. The amplification factor and the collection efficiency were recorded by chronoamperometry. Cyclic voltammetry (CV) was utilized to determine the oxidation and reduction potentials as well as for monitoring the electron transfer process. The different deposited carbon materials were characterized by Raman spectroscopy.At present, we successfully fabricated carbon nanogaps down to 80 nm and we are convinced to reach the present fabrication limit of about 30 nm (for gold and platinum electrodes) with carbon as electrode material as well. To the best of our knowledge, this is the first IDA nanogap sensor, which features a gap distance under 100 nm with amorphous carbon as electrode material. Moreover, we present a signal amplification of 32 for carbon electrodes by redox cycling, which is the highest reported amplification so far.
Here we present the highly sensitive detection of dopamine using gold nanogap IDAs with redox-cycling amplification. Through the combination with a facile electrochemical activation and a chronoamperometric multistep protocol fouling of the gold electrode surface can be prevented and a sensitivity of 14 nA μM -1 with excellent linearity up to 10 μM is achieved. The low-cost and reproducible wafer level fabrication process of the nanogap IDAs plays a key role. Electrode and substrate materials can be nearly arbitrarily chosen. Also the gap sizes could be adjusted down to sub-100 nm dimensions with this versatile approach, allowing for very high signal amplification. In comparison to the current gold standard, fastscan cyclic voltammetry (FSCV) with carbon fiber microelectrodes (CFMEs), which suffers from high background currents, no elaborate data processing and high-end electronic equipment is needed. Employing our flexible, easy and inexpensive method, DA monitoring with a short acquisition period and a detection limit less than 200 nM is successfully demonstrated.
The electricity demand due to the increasing number of EVs presents new challenges for the operation of the electricity network, especially for the distribution grids. The existing grid infrastructure may not be sufficient to meet the new demands imposed by the integration of EVs. Thus, EV charging may possibly lead to reliability and stability issues, especially during the peak demand periods. Demand side management (DSM) is a potential and promising approach for mitigation of the resulting impacts. In this work, we developed an autonomous DSM strategy for optimal charging of EVs to minimize the charging cost and we conducted a simulation study to evaluate the impacts to the grid operation. The proposed approach only requires a one way communicated incentive. Real profiles from an Austrian study on mobility behavior are used to simulate the usage of the EVs. Furthermore, real smart meter data are used to simulate the household base load profiles and a real low voltage grid topology is considered in the load flow simulation. Day-ahead electricity stock market prices are used as the incentive to drive the optimization. The results for the optimum charging strategy is determined and compared to uncontrolled EV charging. The results for the optimum charging strategy show a potential cost saving of about 30.8% compared to uncontrolled EV charging. Although autonomous DSM of EVs achieves a shift of load as pursued, distribution grid operation may be substantially affected by it. We show that in the case of real time price driven operation, voltage drops and elevated peak to average powers result from the coincident charging of vehicles during favourable time slots.
Background: Peripheral arterial disease (PAD) is a common and severe disease with a highly increased cardiovascular morbidity and mortality. Through the circulatory disorder and the linked undersupply of oxygen carriers in the lower limbs, the ongoing decrease of the pain-free walking distance occurs with a significant reduction in patients’ quality of life. Studies including activity monitoring for patients with PAD are rare and digital support to increase activity via mobile health technologies is mainly targeted at patients with cardiovascular disease in general. The special requirement of patients with PAD is the need to reach a certain pain level to improve the pain-free walking distance. Unfortunately, both poor adherence and availability of institutional resources are major problems in patient-centered care.
Objective: The objective of this trackPAD pilot study is to evaluate the feasibility of a mobile phone–based self tracking app to promote physical activity and supervised exercise therapy (SET) in particular. We also aim for a subsequent patient centered adjustment of the app prototype based on the results of the app evaluation and process evaluation.
Methods: This study was designed as a closed user group trial, with assessors blinded, and parallel group study with face-to-face components for assessment with a follow-up of 3 months. Patients with symptomatic PAD (Fontaine stage IIa or IIb) and possession of a mobile phone were eligible. Eligible participants were randomly assigned into study and control group, stratified by their distance covered in the 6-min walk test, using the software TENALEA. Participants randomized to the study group received usual care and the mobile intervention (trackPAD) for the follow-up period of 3 months, whereas participants randomized to the control group received only usual care. TrackPAD records the frequency and duration of training sessions and pain level using manual user input. Clinical outcome data were collected at the baseline and after 3 months via validated tools (6-min walk test, ankle-brachial index, and duplex ultrasound at the lower arteries) and self-reported quality of life. Usability and quality of the app was determined using the user version of the Mobile Application Rating Scale.
Results: The study enrolled 45 participants with symptomatic PAD (44% male). Of these participants, 21 (47%) were randomized to the study group and 24 (53%) were randomized to the control group. The distance walked in the 6-min walk test was comparable in both groups at baseline (study group: mean 368.1m [SD 77.6] vs control group: mean 394.6m [SD 100.6]).
Conclusions: This is the first trial to test a mobile intervention called trackPAD that was designed especially for patients with PAD. Its results will provide important insights in terms of feasibility, effectiveness, and patient preferences of an app-based mobile intervention supporting SET for the conservative treatment of PAD.