Refine
Document Type
- Article (12)
- Conference Proceeding (7)
Institute
Is part of the Bibliography
- yes (19)
Keywords
- AWG (1)
- AWG-parameters tool (1)
- Arrayed waveguide gratings (1)
- Couplers (1)
- Crosstalk (1)
- OCT on-chip (1)
- Optical fiber sensors (1)
- Photonics (1)
- Refractive index (1)
- Si3N4 (1)
Electric cell-substrate impedance spectroscopy (ECIS) enables non-invasive and continuous read-out of electrical parameters of living tissue. The aim of the current study was to investigate the performance of interdigitated sensors with 50 μm electrode width and 50 μm inter-electrode distance made of gold, aluminium, and titanium for monitoring the barrier properties of epithelial cells in tissue culture. At first, the measurement performance of the photolithographic fabricated sensors was characterized by defined reference electrolytes. The sensors were used to monitor the electrical properties of two adherent epithelial barrier tissue models: renal proximal tubular LLC-PK1 cells, representing a normal functional transporting epithelium, and human cervical cancer-derived HeLa cells, forming non-transporting cancerous epithelial tissue. Then, the impedance spectra obtained were analysed by numerically fitting the parameters of the two different models to the measured impedance spectrum. Aluminium sensors proved to be as sensitive and consistent in repeated online-recordings for continuous cell growth and differentiation monitoring assensors made of gold, the standard electrode material. Titanium electrodes exhibited an elevated intrinsic ohmic resistance incomparison to gold reflecting its lower electric conductivity. Analysis of impedance spectra through applying models and numerical data fitting enabled the detailed investigation of the development and properties of a functional transporting epithelial tissue using either gold or aluminium sensors. The result of the data obtained, supports the consideration of aluminium and titanium sensor materials as potential alternatives to gold sensors for advanced application of ECIS spectroscopy.
Compact and high-resolution 256-channel silicon nitride based AWG-spectrometer for OCT on a chip
(2019)
We present design, simulation and technological verification of a compact 256-channel, 42-GHz silicon nitride based AWG-spectrometer. The spectrometer was designed for TM-polarized light with a central wavelength of 850 nm, applying “AWG-Parameters” tool. This design is based on a previous study of various AWG designs (8-channel, 100-GHz; 20-channel, 50-GHz; 40-channel, 50-GHz, 80-channel, 50-GHz and 160-channel, 50-GHz AWGs), which were all technologically verified. The spectrometer features small size and high resolution. It is integrated on OCT chip using standard CMOS processes. The SD-OCT system is developed to operate in a wavelength range from 800 nm to 900 nm, having 0.1 nm resolution.