Compact and high-resolution 256-channel silicon nitride based AWG-spectrometer for OCT on a chip
(2019)
We present design, simulation and technological verification of a compact 256-channel, 42-GHz silicon nitride based AWG-spectrometer. The spectrometer was designed for TM-polarized light with a central wavelength of 850 nm, applying “AWG-Parameters” tool. This design is based on a previous study of various AWG designs (8-channel, 100-GHz; 20-channel, 50-GHz; 40-channel, 50-GHz, 80-channel, 50-GHz and 160-channel, 50-GHz AWGs), which were all technologically verified. The spectrometer features small size and high resolution. It is integrated on OCT chip using standard CMOS processes. The SD-OCT system is developed to operate in a wavelength range from 800 nm to 900 nm, having 0.1 nm resolution.
Das semantische Differential am Beispiel einer Untersuchung zu Food Design in der Werbefotografie.
(2015)
Optoelectronic system based on photonic integrated circuits to miniaturize spectral domain OCT
(2023)
We present a miniaturized optical coherence tomography (OCT) setup based on photonic integrated circuits (PIC) for the 850 nm range. We designed a 512-channel arrayed waveguide grating (AWG) on a PIC for spectral domain OCT (SD-OCT) that is co-integrated with PIN-photodiodes and analog-to-digital-converters on one single chip. This image sensor is combined with all the necessary electronics to act as a camera. It is integrated into a fiber-based OCT system, achieving a sensitivity of >80dB and various samples are imaged. This optoelectronic system will allow building small and cost-effective OCT systems to monitor retinal diseases.
We present the technological verification of a size-optimized 160-channel, 50-GHz silicon nitride-based AWG-spectrometer. The spectrometer was designed for TM-polarized light with a central wavelength of 850 nm applying our proprietary “AWG-Parameters” tool. For the simulations of AWG layout, the WDM PHASAR photonics tool from Optiwave was used. The simulated results show satisfying optical properties of the designed AWG-spectrometer. However, the high-channel count causes a large AWG size with standard design approaches. To solve this problem we designed a special taper enabling the reduction of AWG structure by about 15% while keeping the same optical properties. The AWG design was fabricated and the measured spectra not only confirm the proposed size-reduction but also the improvement of optical properties of the size-optimized AWG.