Forschungszentrum Energie
Refine
Year of publication
Document Type
- Conference Proceeding (29) (remove)
Institute
- Forschungszentrum Energie (29)
- Josef Ressel Zentrum für Intelligente Thermische Energiesysteme (4)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (2)
- Forschung (2)
- Forschungszentrum Business Informatics (2)
- Forschungszentrum Mikrotechnik (2)
- Technik | Engineering & Technology (2)
- Josef Ressel Zentrum für Materialbearbeitung (1)
Keywords
- Demand side management (2)
- Color (1)
- Data mining (1)
- Domestic hot water heater (1)
- Electric vehicles (1)
- Grey Box (1)
- HVAC (1)
- Live steam prediction (1)
- Materials (1)
- Measurement by laser beam (1)
Flexibility estimation is the first step necessary to incorporate building energy systems into demand side management programs. We extend a known method for temporal flexibility estimation from literature to a real-world residential heat pump system, solely based on historical cloud data. The method proposed relies on robust simplifications and estimates employing process knowledge, energy balances and manufacturer's information. Resulting forced and delayed temporal flexibility, covering both domestic hot water and space heating demands as constraints, allows to derive a flexibility range for the heat pump system. The resulting temporal flexibility lay within the range of 24 minutes and 6 hours for forced and delayed flexibility, respectively. This range provides new insights into the system's behaviour and is the basis for estimating power and energy flexibility - the first step necessary to incorporate building energy systems into demand side management programs.
Bubble column humidifiers (BCHs) are frequently used for the humidification of air in various water treatment applications. A potential but not yet profoundly investigated application of such devices is the treatment of oily wastewater. To evaluate this application, the accumulation of an oil-water emulsion using a BCH is experimentally analyzed. The amount of evaporating water vapor can be evaluated by measuring the humidity ratio of the outlet air. However, humidity measurements are difficult in close to saturated conditions, as the formation of liquid droplets on the sensor impacts the measurement accuracy. We use a heating section after the humidifier, such that no liquid droplets are formed on the sensor. This enables us a more accurate humidity measurement. Two batch measurement runs are conducted with (1) tap water and (2) an oil-water emulsion as the respective liquid phase. The humidity measurement in high humidity conditions is highly accurate with an error margin of below 3 % and can be used to predict the oil concentration of the remaining liquid during operation. The measured humidity ratio corresponds with the removed amount of water vapor for both tap water and the accumulation of an oil-water emulsion. Our measurements show that the residual water content
in the oil-water emulsion is below 4 %.