Forschungszentrum Energie
Refine
Year of publication
Document Type
- Article (51)
- Conference Proceeding (29)
- Doctoral Thesis (4)
- Book (2)
- Master's Thesis (1)
- Preprint (1)
Institute
- Forschungszentrum Energie (88)
- Josef Ressel Zentrum für Intelligente Thermische Energiesysteme (6)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (5)
- Technik | Engineering & Technology (5)
- Forschungszentrum Business Informatics (3)
- Forschung (2)
- Forschungszentrum Mikrotechnik (2)
- Josef Ressel Zentrum für Materialbearbeitung (1)
- Wirtschaft (1)
Language
- English (79)
- German (8)
- Multiple languages (1)
Keywords
- Demand side management (6)
- Demand response (3)
- Desalination (3)
- Grid balancing (3)
- Optimization (3)
- Autonomous optimization (2)
- Bubble column humidifier (2)
- Demand Side Management (2)
- Distributed storage (2)
- Distribution grids (2)
Bubble column humidifiers (BCHs) are frequently used for the humidification of air in various water treatment applications. A potential but not yet profoundly investigated application of such devices is the treatment of oily wastewater. To evaluate this application, the accumulation of an oil-water emulsion using a BCH is experimentally analyzed. The amount of evaporating water vapor can be evaluated by measuring the humidity ratio of the outlet air. However, humidity measurements are difficult in close to saturated conditions, as the formation of liquid droplets on the sensor impacts the measurement accuracy. We use a heating section after the humidifier, such that no liquid droplets are formed on the sensor. This enables us a more accurate humidity measurement. Two batch measurement runs are conducted with (1) tap water and (2) an oil-water emulsion as the respective liquid phase. The humidity measurement in high humidity conditions is highly accurate with an error margin of below 3 % and can be used to predict the oil concentration of the remaining liquid during operation. The measured humidity ratio corresponds with the removed amount of water vapor for both tap water and the accumulation of an oil-water emulsion. Our measurements show that the residual water content
in the oil-water emulsion is below 4 %.
The humidification-dehumidification process (HDH) for desalination is a promising technology to address water scarcity issues in rural regions. However, a low humidifier efficiency is a weakness of the process. Bubble column humidifiers (BCH) are promising for HDH, as they provide enhanced heat and mass transfer and have low maintenance requirements. Previous studies of HDH-systems with BCHs draw different conclusions regarding the impact of superficial air velocity and liquid height on the humidification. Furthermore, the impact of flow characteristics has never been investigated systematically at all. In this study, an optimized BCH test setup that allows for optical analysis of the humidifier is used and evaluated. Our test setup is validated, since the influence of water temperature on the humidification, which is exponential, is reproduced. Measurements with seawater show that the normalised system productivity is increased by about 56 % with an increase in superficial air velocity from 0.5 to 5 cm/s. Furthermore, the system productivity is increased by around 29 % with an increase in liquid height from 60 to 378 mm. While the impact of superficial air velocity can be traced back to temperature changes at the humidifier and dehumidifier outlets, the impact of liquid height is shown to be caused by a smaller heat loss surface in the humidifier with an increase in liquid height. For the impact of sieve plate orifice diameter, a clear influence on the humidification is not apparent, this parameter needs to be investigated further. Finally, our new test setup allows for analysing the humidification of air (1) in a systematic way, (2) in relevant measurement ranges and (3) in comparison with optical analyses of the flow characteristics.