An electrochemical study with three redox substances on a carbon based nanogap electrode array
(2020)
We report resent results on the fabrication and characterization of carbon nanogap interdigitated electrode arrays (IDAs) for biosensor applications based on redox cycling. The electrochemical results of the carbon electrodes are compared to our fabricated gold electrodes with similar nanogap distances. The amplification factor and the collection efficiency were recorded by chronoamperometry. Cyclic voltammetry (CV) was utilized to determine the oxidation and reduction potentials as well as for monitoring the electron transfer process. The different deposited carbon materials were characterized by Raman spectroscopy.At present, we successfully fabricated carbon nanogaps down to 80 nm and we are convinced to reach the present fabrication limit of about 30 nm (for gold and platinum electrodes) with carbon as electrode material as well. To the best of our knowledge, this is the first IDA nanogap sensor, which features a gap distance under 100 nm with amorphous carbon as electrode material. Moreover, we present a signal amplification of 32 for carbon electrodes by redox cycling, which is the highest reported amplification so far.
Whether at the intramolecular or cellular scale in organisms, cell-cell adhesion adapt to external mechanical cues arising from the static environment of cells and from dynamic interactions between neighboring cells. Cell-cell adhesions need to resist detachment forces to secure the integrity and internal organization of organisms. In the past, various techniques have been developed to characterize adhesion properties of molecules and cells in vitro, and to understand how cells sense and probe their environment. Atomic force microscopy and dual-pipette aspiration, where cells are mainly present in suspension, are common methods for studying detachment forces of cell-cell adhesions. How cell-cell adhesion forces are developed for adherent and environment-adapted cells, however, is less clear. Here, we designed the Cell-Cell Separation Device (CC-SD), a microstructured substrate that measures both intercellular forces and external stresses of cells towards the matrix. The design is based on micropillar arrays originally designed for cell traction-force measurements. We designed PDMS micropillar-blocks, to which cells could adhere and be able to connect to each other across the gap. Controlled stretching of the whole substrate changed the distance between blocks and increased gap size. That allowed us to apply strains to cell-cell contacts, eventually leading to cell-cell adhesion detachment, which was measured by pillar deflections. The CC-SD provided an increase of the gap between the blocks of up to 2.4-fold, which was sufficient to separate substrate-attached cells with fully developed F-actin network. Simultaneously measured pillar deflections allowed us to address cellular response to the intercellular strain applied. The CC-SD thus opens up possibilities for the analysis of intercellular force detachments and sheds light on the robustness of cell-cell adhesions in dynamic processes in tissue development.
Combining parallel pattern generation of electrohydrodynamic lithography with serial addressing
(2018)
Recently the use of microRNAs (miRNAs) as biomarkers for a multitude of diseases has gained substantial significance for clinical as well as point-of-care diagnostics. Amongst other challenges, however, it holds the central requirement that the concentration of a given miRNA must be evaluated within the context of other factors in order to unambiguously diagnose one specific disease. In terms of the development of diagnostic methods and devices, this implies an inevitable demand for multiplexing in order to be able to gauge the abundance of several components of interest in a patient’s sample in parallel. In this study, we design and implement different multiplexed versions of our electrochemical microfluidic biosensor by dividing its channel into subsections, creating four novel chip designs for the amplification-free and simultaneous quantification of up to eight miRNAs on the CRISPR-Biosensor X (‘X’ highlighting the multiplexing aspect of the device). We then use a one-step model assay followed by amperometric readout in combination with a 2-minute-stop-flow-protocol to explore the fluidic and mechanical characteristics and limitations of the different versions of the device. The sensor showing the best performance, is subsequently used for the Cas13a-powered proof-of-concept measurement of two miRNAs (miRNA-19b and miRNA-20a) from the miRNA-17∼92 cluster, which is dysregulated in the blood of pediatric medulloblastoma patients. Quantification of the latter, alongside simultaneous negative control measurements are accomplished on the same device. We thereby confirm the applicability of our platform to the challenge of amplification-free, parallel detection of multiple nucleic acids.