Refine
Year of publication
- 2023 (47) (remove)
Document Type
- Article (47) (remove)
Institute
- Wirtschaft (16)
- Forschungszentrum Mikrotechnik (10)
- Soziales & Gesundheit (8)
- Forschungszentrum Business Informatics (4)
- Forschungszentrum Human Centred Technologies (4)
- Forschungszentrum Energie (3)
- Forschung (2)
- Josef Ressel Zentrum für Intelligente Thermische Energiesysteme (2)
- Forschungsgruppe Empirische Sozialwissenschaften (1)
- Gestaltung (1)
Keywords
- Schreibdidaktik (3)
- Business Analytics (2)
- Controlling (2)
- Excel (2)
- Prognose (2)
- Zeitreihenanalyse (2)
- AWG (1)
- AWG-spectrometer (1)
- Akademisierung (1)
- Anthropocentrism (1)
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.
Organic acidurias (OAs), urea-cycle disorders (UCDs), and maple syrup urine disease (MSUD) belong to the category of intoxication-type inborn errors of metabolism (IT-IEM). Liver transplantation (LTx) is increasingly utilized in IT-IEM. However, its impact has been mainly focused on clinical outcome measures and rarely on health-related quality of life (HRQoL). Aim of the study was to investigate the impact of LTx on HrQoL in IT-IEMs. This single center prospective study involved 32 patients (15 OA, 11 UCD, 6 MSUD; median age at LTx 3.0 years, range 0.8–26.0). HRQoL was assessed pre/post transplantation by PedsQL-General Module 4.0 and by MetabQoL 1.0, a specifically designed tool for IT-IEM. PedsQL highlighted significant post-LTx improvements in total and physical functioning in both patients' and parents' scores. According to age at transplantation (≤3 vs. >3 years), younger patients showed higher post-LTx scores on Physical (p = 0.03), Social (p < 0.001), and Total (p =0.007) functioning. MetabQoL confirmed significant post-LTx changes in Total and Physical functioning in both patients and parents scores (p ≤ 0.009). Differently from PedsQL, MetabQoL Mental (patients p = 0.013, parents p = 0.03) and Social scores (patients p = 0.02, parents p = 0.012) were significantly higher post-LTx. Significant improvements (p = 0.001–0.04) were also detected both in self- and proxy-reports for almost all MetabQoL subscales. This study shows the importance of assessing the impact of transplantation on HrQoL, a meaningful outcome reflecting patients' wellbeing. LTx is associated with significant improvements of HrQol in both self- and parentreports. The comparison between PedsQL-GM and MetabQoL highlighted that MetabQoL demonstrated higher sensitivity in the assessment of diseasespecific domains than the generic PedsQL tool.
Signatures of the optical stark effect on entangled photon pairs from resonantly-pumped quantum dots
(2023)
Two-photon resonant excitation of the biexciton-exciton cascade in a quantum dot generates highly polarization-entangled photon pairs in a near-deterministic way. However, the ultimate level of achievable entanglement is still debated. Here, we observe the impact of the laser-induced ac-Stark effect on the quantum dot emission spectra and on entanglement. For increasing pulse-duration-to-lifetime ratios and pump powers, decreasing values of concurrence are recorded. Nonetheless, additional contributions are still required to fully account for the observed below-unity concurrence.
Schreiblehre und KI – Teil 3: Erste Schlussfolgerungen aus dieser Erfahrung für die Schreiblehre
(2023)
Redundanz und Varietät
(2023)
Optoelectronic system based on photonic integrated circuits to miniaturize spectral domain OCT
(2023)
We present a miniaturized optical coherence tomography (OCT) setup based on photonic integrated circuits (PIC) for the 850 nm range. We designed a 512-channel arrayed waveguide grating (AWG) on a PIC for spectral domain OCT (SD-OCT) that is co-integrated with PIN-photodiodes and analog-to-digital-converters on one single chip. This image sensor is combined with all the necessary electronics to act as a camera. It is integrated into a fiber-based OCT system, achieving a sensitivity of >80dB and various samples are imaged. This optoelectronic system will allow building small and cost-effective OCT systems to monitor retinal diseases.