Refine
Year of publication
- 2019 (94) (remove)
Document Type
- Conference Proceeding (48)
- Article (23)
- Part of a Book (12)
- Book (7)
- Doctoral Thesis (1)
- Other (1)
- Periodical (1)
- Part of Periodical (1)
Institute
- Forschungszentrum Mikrotechnik (28)
- Forschungszentrum Business Informatics (17)
- Wirtschaft (13)
- Soziales & Gesundheit (12)
- Technik | Engineering & Technology (9)
- Forschungszentrum Energie (8)
- Forschungszentrum Human Centred Technologies (8)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (6)
- Didaktik (mit 31.03.2021 aufgelöst; Integration ins TELL Center) (5)
- Department of Engineering (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (3)
Is part of the Bibliography
- yes (94) (remove)
Keywords
ÖMG Conference 2019
(2019)
In dieser Arbeit wird Supervised Learning verwendet, um die Zuverlässigkeit von Schweißverbindungen zu evaluieren.
Um die Schweißqualität zu bestimmen, wurden End of Life Tests durchgeführt. Für die statistische Auswertung und Vorhersage der zu erwartenden Lebensdauer, wurden die Daten basierend auf einer logarithmischen Normalverteilung und mit einer multivariablen linearen Regression modelliert. Um die signifikanten Einflussfaktoren zu identifizieren, wurde eine schrittweise Regression genutzt. Die Ergebnisse zeigen, dass das entwickelte Modell die Zuverlässigkeit und Lebensdauer der Schweißverbindung akkurat abbildet und präzise Vorhersagen liefern kann.
Stress testing is part of today’s bank risk management and often required by the governing regulatory authority. Performing such a stress test with stress scenarios derived from a distribution, instead of pre-defined expert scenarios, results in a systematic approach in which new severe scenarios can be discovered. The required scenario distribution is obtained from historical time series via a Vector-Autoregressive time series model. The worst-case search, i.e. finding the scenario yielding the most severe situation for the bank, can be stated as an optimization problem. The problem itself is a constrained optimization problem in a high-dimensional search space. The constraints are the box constraints on the scenario variables and the plausibility of a scenario.
The latter is expressed by an elliptic constraint. As the evaluation of the stress scenarios is performed with a simulation tool, the optimization problem can be seen as black-box optimization problem. Evolution Strategy, a well-known optimizer for black-box problems, is applied here. The necessary adaptations to the algorithm are explained and a set of different algorithm design choices are investigated. It is shown that a simple box constraint handling method, i.e. setting variables which violate a box constraint to the respective boundary of the feasible domain, in combination with a repair of implausible scenarios provides good results.
Was ist zu tun?
(2019)
Varying mindsets in Design Thinking. Why they change during the process and how to nudge them
(2019)
Adult muscle carnitine palmitoyltransferase (CPT) II deficiency is a rare autosomal recessive disorder of long-chain fatty acid metabolism. It is typically associated with recurrent episodes of exercise-induced rhabdomyolysis and myoglobinuria, in most cases caused by a c.338C > T mutation in the CPT2 gene. Here we present the pedigree of one of the largest family studies of CPT II deficiency caused by the c.338C > T mutation, documented so far. The pedigree comprises 24 blood relatives
of the index patient, a 32 year old female with genetically proven CPT II deficiency. In total, the mutation was detected in 20 family members, among them five homozygotes and 15 heterozygotes. Among all homozygotes, first symptoms of CPT II deficiency occurred during childhood. Additionally, two already deceased relatives of the index patient were carriers of at least one copy of the genetic variant, revealing a remarkably high prevalence of the c.338C > T mutation within the tested family. Beside the index patient, only one individual had been diagnosed with CPT II deficiency prior to this study and three cases of CPT II deficiency were newly detected by this family study, pointing
to a general underdiagnosis of the disease. Therefore, this study emphasizes the need to raise awareness of CPT II deficiency for correct diagnosis and accurate management of the disease.
Zusammenfassung: Eine umfassende Literaturrecherche (Comprehensive Literature Search, CLS) bezeichnet eine umfangreiche und aufwändige Recherche mit dem Ziel, möglichst alle Studien zur Beantwortung einer zugrundeliegenden Forschungsfrage im Rahmen einer systematischen Übersichtsarbeit zu identifizieren. Konkrete Empfehlungen oder eine Definition des Begriffs CLS gibt es jedoch nicht. Der vorliegende Beitrag führt in eine Rahmung der CLS ein, stellt die damit einhergehenden Herausforderungen dar und weist auf methodische Implikationen sowie mögliche zukünftige Forschungsbereiche hin.
Transparent laser-structured glasses with superhydrophilic properties for anti-fogging applications
(2019)
Ultrashort pulse laser structuring enables direct modification of glass surfaces to generate superhydrophilic properties for anti-fogging applications. This approach makes coatings dispensable and the generated surfaces remain thermally, mechanically, and chemically resistant. However, the laser-generated structures usually cause scattering, which decreases transmission and may disturb the vision through the modified glass in the dry state. The aim of this study was to find a laser-processing strategy to achieve superhydrophilic, anti-fogging properties on glass surfaces with maximum transmission and minimal visual perception of the generated structure. For this purpose, we used an ultrashort-pulsed laser to generate periodic patterns of rippled circles or rough holes with varying pitch. The water contact angle and transmission of the structured glasses were measured as a function of the structured area. It was found that a periodic pattern of holes, which covers less than 1% of the surface, is already sufficient to reach the superhydrophilic state (contact angle < 5°) and provides nearly the same transmission as pristine glass. Pictures of objects imaged through dry, structured glasses, which were placed close to the lens or object, showed in both cases only a minimal decrease of contrast. If this minor drawback can be accepted, this direct laser structuring approach could be an interesting alternative to coating-based techniques and leaves even room to apply additional coatings for the fabrication of multi-functional special glasses.
During two studies the influence of technologies on sleep were analyzed. The first one is about the effect of light on the circadian rhythm and as a consequence on sleep quality of persons in a vegetative state. The second one, which is still running, surveys the influence of several technologies on the sleep of elderly people living in a nursing home.
We present the technological verification of a size-optimized 160-channel, 50-GHz silicon nitride-based AWG-spectrometer. The spectrometer was designed for TM-polarized light with a central wavelength of 850 nm applying our proprietary “AWG-Parameters” tool. For the simulations of AWG layout, the WDM PHASAR photonics tool from Optiwave was used. The simulated results show satisfying optical properties of the designed AWG-spectrometer. However, the high-channel count causes a large AWG size with standard design approaches. To solve this problem we designed a special taper enabling the reduction of AWG structure by about 15% while keeping the same optical properties. The AWG design was fabricated and the measured spectra not only confirm the proposed size-reduction but also the improvement of optical properties of the size-optimized AWG.
Selbst sicher sein
(2019)
Production and tribological characterization of tailored laser-induced surface 3D microtextures
(2019)
Optical splitters are passive optical components, which have found applications in a wide range of telecom, sensing, medical and many other scientific areas.
Low-index contrast optical splitters (Silica-on-Silicon (SoS) based waveguide devices) feature many advantages such as low fiber coupling losses and low propagation losses. They are considered an attractive DWDM solution in the telecommunication for all optical signal processing in optical communication systems. Nowadays the steadily increasing data volume in communication networks is driven by a rapid proliferation of home-based and business computers, storage capacities, processing capabilities and the extensive availability of Internet. The challenge is to transfer high data volumes in short periods of time over high distances as lossless as possible. The task of the optical splitters in Fiber-to-the-x (FTTx) network is to split one optical signal in many identical signals bringing for example the same TV signal in different households. Of course, the more buildings can be served by one optical splitter the lower are the installation costs.
High-index contrast optical splitters (such as silicon, silicon nitride or polymer based waveguide devices) feature much smaller waveguide size compared to low index contrast splitters. Such compact devices can easily be implemented on-chip and have already been used in the development of optical sensors, devices for DNA diagnostics and for infrared spectroscopy.
We will present the latest achievements in the design of two mostly used optical splitters (MMI and Y-branch) and discuss their advantages and disadvantages. Finally, some applications of the splitters developed in the frame of various projects will be presented.
This work was carried out in the framework of the project PHOCOP (no. SK-AT-2017-0013) and NAMOPRISIN (no. SK-AT-2017-0005) from the Slovak research and development agency of the Ministry of Education, Science, Research and Sport of the Slovak Republic and SK 16/2018 and 15/2018 from OeAD-GmbH.
On the extension of digital ecosystems for SCM and customs with distributed ledger technologies
(2019)
Global supply chains represent the backbone of the modern manufacturing industry. Planning of global supply chains still represents a major hurdle, mainly because of the high complexity and unforeseen disruptions that have to be mastered for meeting the different logistics windows in a globally distributed production environment. Trust in supply chains is an additional challenge. A major – albeit sometimes overlooked - part of Supply Chain Management (SCM) is the management and integration of customs processes, clearing of tariffs, (re-)billing of customers, and fulfilling other legal requirements related to crossing borders, ranging from environmental standards over goods inspection to general paper work. With the exception of work offered by the World Customs Organization (WCO) the issue of customs and blockchain is still underrepresented in research and practice. In this paper, we look at innovations that drive the current ICTenabled SCM research and how these can be combined with smart customs management. After a literature review and introduction to the state-of-the-art, we list potential trust-based innovations for SCM and customs in digital business ecosystems. Based upon the innovations we also describe a requirements analysis of existing distributed ledger technologies (requirements for system layout, system configuration, system governance). A description of the prototype for the Lake Constance region – on which we are currently working – concludes the paper.
Breath analysis holds great promise for real-time and non-invasive medical diagnosis. Thus, there is a considerable need for simple-in-use and portable analyzers for rapid detection of breath indicators for different diseases in their early stages. Sensor technology meets all of these demands. However, miniaturized breath analyzers require adequate breath sampling methods. In this context, we propose non-contact sampling; namely the collection of breath samples by exhalation from a distance into a miniaturized collector without bringing the mouth into direct contact with the analyzing device. To evaluate this approach different breathing maneuvers have been tested in a real-time regime on a cohort of 23 volunteers using proton transfer reaction mass spectrometry. The breathing maneuvers embraced distinct depths of respiration, exhalation manners, size of the mouth opening and different sampling distances. Two inhalation modes (normal, relaxed breathing and deep breathing) and two exhalation manners (via smaller and wider lips opening) forming four sampling scenarios were selected. A sampling distance of approximately 2 cm was found to be a reasonable trade-off between sample dilution and requirement of no physical contact of the subject with the analyzer. All four scenarios exhibited comparable measurement reproducibility spread of around 10%. For normal, relaxed inspiration both dead-space and end-tidal phases of exhalation lasted approximately 1.5 s for both expiration protocols. Deep inhalation prolongs the end-tidal phase to about 3 s in the case of blowing via a small lips opening, and by 50% when the air is exhaled via a wide one. In conclusion, non-contact breath sampling can be considered as a promising alternative to the existing breath sampling methods, being relatively close to natural spontaneous breathing.
Lead–magnesium niobate lead titanate (PMN-PT) has been proven as an excellent material for sensing and actuating applications. The fabrication of advanced ultra-small PMN-PT-based devices relies on the availability of sophisticated procedures for the micro-machining of PMN-PT thin films or bulk substrates. Approaches reported up to date include chemical etching, excimer laser ablation, and ion milling. To ensure an excellent device performance, a key mandatory feature for a micro-machining process is to preserve as far as possible the crystalline quality of the substrates; in other words, the fabrication method must induce a low density of cracks and other kind of defects. In this work, we demonstrate a relatively fast procedure for the fabrication of high-quality PMN-PT micro-machined actuators employing green femtosecond laser pulses. The fabricated devices feature the absence of extended cracks and well-defined edges with relatively low roughness, which is advantageous for the further integration of nanomaterials onto the piezoelectric actuators.
Interstitial photodynamic therapy (iPDT) treats malignant brain cancer cells by irradiation with low power laser light. The light is guided into the human body by diffuse emitting fibers. This study targets the light distribution of optical diffusers within the brain tissue. It was shown, that by submerging an optical diffuser into human brain phantom, its radiation profile measured in air converges towards a Gaussian distribution with increasing phantom depth. A camera method using digital averaging filters as well as an integrating sphere setup, both, smoothing the diffuser radiation profile were applied onto the evaluated diffuser.
Learning together
(2019)
Investigations on mechanical stability of laser machined optical fibre tips for medical application
(2019)
Light delivery is a challenging task, when it comes to medical applications. The light is guided through optical fibers from the light source towards the treatment region. In case of interstitial light application, the light has to be decoupled from the fibre and spread to the surrounding tissue. To reach larger tissue volumes, this can be either obtained by adding a scattering volume to the tip of the fibre, or by directly modifying the optical fibre itself in order to break the total reflection within the fibre core. Such modifications can be either on the fibre surface itself or internally in the fibre core. One approach to obtain the fibre structuring could be laser induced surface roughening using an ultrafast laser source. While using volume scattering as diffusor at the fibre tip is currently the gold standard for non-thermal applications (< 0.3W/cm), the decoupling of high power laser intensities for thermal treatment options is still challenging. Structuring the fibre core itself usually is related with a loss of mechanical stability. As fibre breakage and potential loss within the human body can have serious consequences, the mechanical stability is one of the quality criterion in diffuser manufacturing. Therefore, investigations about the mechanical stability of laser manufactured optical fibre diffusers are needed.
In order to evaluate the mechanical stability, a 4-point as well as a 2-point breaking test were developed. Different fibre diffusers, based on volume or surface scattering, were manufactured using fs-laser ablation techniques and its breaking strengths were investigated.
It could be shown that for surface fibre modifications, the mechanical stability reduces with increasing defect depth. The stability significantly drops when the laser ablation was performed in the thermal energy range. Volume scattering modified fibres only showed a slight reduction in stability compared to un-machined fibres.
In conclusion, internal fibre modification seems to be the most promising method to establish optical fibre diffusers, which are capable of several watts of emission power, while preserving its mechanical strength.
Here we present the highly sensitive detection of dopamine using gold nanogap IDAs with redox-cycling amplification. Through the combination with a facile electrochemical activation and a chronoamperometric multistep protocol fouling of the gold electrode surface can be prevented and a sensitivity of 14 nA μM -1 with excellent linearity up to 10 μM is achieved. The low-cost and reproducible wafer level fabrication process of the nanogap IDAs plays a key role. Electrode and substrate materials can be nearly arbitrarily chosen. Also the gap sizes could be adjusted down to sub-100 nm dimensions with this versatile approach, allowing for very high signal amplification. In comparison to the current gold standard, fastscan cyclic voltammetry (FSCV) with carbon fiber microelectrodes (CFMEs), which suffers from high background currents, no elaborate data processing and high-end electronic equipment is needed. Employing our flexible, easy and inexpensive method, DA monitoring with a short acquisition period and a detection limit less than 200 nM is successfully demonstrated.