Refine
Year of publication
Document Type
- Conference Proceeding (137)
- Article (96)
- Part of a Book (3)
- Doctoral Thesis (2)
- Book (1)
- Habilitation (1)
- Other (1)
Institute
- Forschungszentrum Mikrotechnik (241) (remove)
Language
- English (235)
- German (5)
- Multiple languages (1)
Is part of the Bibliography
- yes (241) (remove)
Keywords
- Laser ablation (11)
- Y-branch splitter (11)
- arrayed waveguide gratings (11)
- photonics (8)
- integrated optics (6)
- Arrayed waveguide gratings (5)
- MMI splitter (5)
- OCT (5)
- insertion loss (5)
- AWG (4)
The utilization of lasers in dentistry expands greatly in recent years. For instance, fs-lasers are effective for both drilling and caries prevention, while cw-lasers are useful for adhesive hardening. A cutting-edge application of lasers in dentistry is the debonding of veneers. While there are pre-existing tools for this purpose, there is still potential for improvement. Initial efforts to investigate laser assisted debonding mechanisms with measurements of the optical and mechanical properties of teeth and prosthetic ceramics are presented. Preliminary tests conducted with a laser system used for debonding that is commercially available showed differences in the output power set at the systems console to that at specified distances from the handpiece. Furthermore, the optical properties of the samples (human teeth and ceramics) were characterised. The optical properties of the ceramics should closely resemble those of teeth in terms of look and feel, but they also influence the laser assisted debonding technique and thus must be taken into account. In addition first attempts were performed to investigate the mechanical properties of the samples by means of pump-probe-elastography under a microscope. By analyzing the sample surface up to 20 ns after a fs-laser pulse impact, pressure and shock waves could be detected, which can be utilized to determine the elastic constants of specific materials. Together such investigations are needed to shape the basis for a purely optical approach of debonding of veneers utilizing acoustic waves.
This study presents different approaches to increase the sensing area of NiO based semiconducting metal oxide gas sensors. Micro- and nanopatterned laser induced periodic surface structures (LIPSS) are generated on silicon and Si/SiO2 substrates. The surface morphologies of the fabricated samples are examined by FE SEM. We select the silicon samples with an intermediate Si3N4 layer due to its superior isolation quality over the thermal oxide for evaluating the hydrogen and acetone sensitivity of a NiO based test sensor.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2023)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.
Parametric anti-resonance is a phenomenon that occurs in systems with at least two degrees of freedom; this can be achieved by periodically exciting some parameters of the system. The effect of this properly tuned periodicity is to increase the dissipation in the system, which leads to a raising in the effective damping of vibrations. This contribution presents the design of an open-loop control to reduce the settling time using the anti-resonance concept. The control signal consists of a quasi-periodic signal capable of transferring the system’s oscillations from one mode to another mode of the system. The general averaging technique is used to characterize the dynamics, particularly the so-called slow dynamics of motion. With this analysis, the control signal is designed for the potential application of a microelectromechanical sensor arrangement; for this specific example, up to 96.8% reduction of settling time is achieved.
In this work, parametric excitation is introduced in a fully balanced flexible rotor mounted on two identical active gas foil bearings. The active gas foil bearings change the top foil shape harmonically with a specific amplitude and frequency. The deformable foil shape is approximated by an analytical function, while the gas pressure distribution is evaluated by the numerical solution of the Reynolds equation for compressible flow. The harmonic variation of the foil shape generates a respective variation in the bearings’ stiffness and damping properties and the system experiences parametric resonances and antiresonances in specific excitation frequencies. The nonlinear gas bearing forces generate bifurcations in the solutions of the system at certain rotating speeds and excitation frequencies; period doubling and Neimark-Sacker bifurcations are noticed in the examined system, and their progress is evaluated as the two bifurcation parameters (rotating speed and parametric excitation frequency) are changed, though a codimension-2 numerical continuation of limit cycles. It is found that at specific range of excitation frequency there are parametric anti-resonances and the bifurcations collide and vanish. Therefore, a bifurcation-free operating range is established and the system can operate stable at a wide speed range.
By a simple femtosecond laser process, we fabricated metal-oxide/gold composite films for electrical and optical gas sensors. We designed a dripple wavelength AWG-spectrometer, matched to the plasma absorption wavelength region of the composite films. H2/CO absorptions fit well with the AWG design for multi gas detection sensor arrays
The main aims of this work are the validation of the developed process of gluing a single-mode optical fiber array with a photonic chip and the selection of a more suitable adhesive from the two adhesives being compared. An active alignment system was used for adjusting the two optical fiber arrays to a photonics chip. The gluing was done by two compared UV curable adhesives applied in the optical path. The insertion losses of glued coupling were measured and investigated at two discrete wavelengths 1310 nm and 1550 nm during temperature testing in the climatic chamber according to Telcordia GR_1209_Corei04 [3]. The measurement, investigation, and comparison of insertion losses of the glued coupling at the spectral band from 1530 nm to 1570 nm were done immediately after gluing process and after three temperature cycles in the climatic chamber with one month delay.
The production of liquid-gas mixtures with desired properties still places high demands on process technology and is usually realized in bubble columns. The physical calculation models used have individual dimensionless factors which, depending on the application, are only valid for small ranges consisting of flow velocity, nozzle geometry and test setup. An iterative but time-consuming design of such dispersion processes is used in industry for producing a liquid-gas mixture according to desired requirements. In the present investigation, we accelerate the necessary design loops by setting up a physical model, which consists of several subsystems that are enriched by dedicated experiments to realize liquid-gas dispersions with low volume fraction and small air bubble diameters in oil. Our approach allows the extraction of individual dimensionless factors from maps of the introduced subsystems. These maps allow for targeted corrective measures of a production process for keeping the quality. The calculation-based approach avoids the need for performing iterative design loops. Overall, this approach supports the controlled generation of liquid-gas mixtures.
In this paper, a 256-channel, 10-GHz arrayed waveguide gratings demultiplexer for ultra-dense wavelength division multiplexing was designed using an in-house developed tool called AWG-Parameters. The AWG demultiplexer was designed for a central wavelength of 1550 nm and the structure was simulated in PHASAR tool from Optiwave. Two different AWG designs were developed and the influence of the design parameters on the AWG performance was studied.