Refine
Year of publication
- 2023 (16) (remove)
Document Type
- Article (10)
- Conference Proceeding (4)
- Preprint (2)
Institute
- Forschungszentrum Mikrotechnik (16) (remove)
Language
- English (16) (remove)
Keywords
- photonics (2)
- 3D MMI splitter (1)
- AWG (1)
- AWG design (1)
- AWG-spectrometer (1)
- Excited States (1)
- Hot States (1)
- Levodopa (1)
- MEMS (1)
- MMI splitter (1)
Signatures of the optical stark effect on entangled photon pairs from resonantly-pumped quantum dots
(2023)
Two-photon resonant excitation of the biexciton-exciton cascade in a quantum dot generates highly polarization-entangled photon pairs in a near-deterministic way. However, the ultimate level of achievable entanglement is still debated. Here, we observe the impact of the laser-induced ac-Stark effect on the quantum dot emission spectra and on entanglement. For increasing pulse-duration-to-lifetime ratios and pump powers, decreasing values of concurrence are recorded. Nonetheless, additional contributions are still required to fully account for the observed below-unity concurrence.
Strain-induced dynamic control over the population of quantum emitters in two-dimensional materials
(2023)
The discovery of quantum emitters in two-dimensional materials has triggered a surge of research to assess their suitability for quantum photonics. While their microscopic origin is still the subject of intense studies, ordered arrays of quantum emitters are routinely fabricated using static strain-gradients, which are used to drive excitons toward localized regions of the 2D crystals where quantum-light-emission takes place. However, the possibility of using strain in a dynamic fashion to control the appearance of individual quantum emitters has never been explored so far. In this work, we tackle this challenge by introducing a novel hybrid semiconductor-piezoelectric device in which WSe2 monolayers are integrated onto piezoelectric pillars delivering both static and dynamic strains. Static strains are first used to induce the formation of quantum emitters, whose emission shows photon anti-bunching. Their excitonic population and emission energy are then reversibly controlled via the application of a voltage to the piezoelectric pillar. Numerical simulations combined with drift-diffusion equations show that these effects are due to a strain-induced modification of the confining-potential landscape, which in turn leads to a net redistribution of excitons among the different quantum emitters. Our work provides relevant insights into the role of strain in the formation of quantum emitters in 2D materials and suggests a method to switch them on and off on demand.
Synthetic polymers, such as polyamide (PA), inherently possess a moderate number of surface functionalities compared to natural polymers, which negatively impacts the uniformity of metallic coatings obtained through wet-chemical methods like electroless plating. The paper presents the use of a siloxane interlayer formed from the condensation of the hydrolyzed 3-triethoxysilylpropyl succinic anhydride (TESPSA) precursor as a strategy to modify the surface properties of polyamide 6.6 (PA66) fabrics and improve the uniformity of the copper surface coating. The application of the siloxane intermediate coating demonstrates a significant improvement in electrical conductivity, up to 20 times higher than fabrics without the interlayer. The morphology of the coatings was investigated using scanning electron (SEM) and laser confocal scanning microscopy (LSM). In addition, dye adsorption, flexural rigidity, air permeability and contact angle measurements were conducted to monitor the change in the PA66 properties after the siloxane functionalization.
Beyond the Four-Level Model: Dark and Hot States in Quantum Dots Degrade Photonic Entanglement
(2023)
Entangled photon pairs are essential for a multitude of quantum photonic applications. To date, the best performing solid-state quantum emitters of entangled photons are semiconductor quantum dots operated around liquid-helium temperatures. To favor the widespread deployment of these sources, it is important to explore and understand their behavior at temperatures accessible with compact Stirling coolers. Here we study the polarization entanglement among photon pairs from the biexciton–exciton cascade in GaAs quantum dots at temperatures up to ∼65 K. We observe entanglement degradation accompanied by changes in decay dynamics, which we ascribe to thermal population and depopulation of hot and dark states in addition to the four levels relevant for photon pair generation. Detailed calculations considering the presence and characteristics of the additional states and phonon-assisted transitions support the interpretation. We expect these results to guide the optimization of quantum dots as sources of highly entangled photons at elevated temperatures.
Whether at the intramolecular or cellular scale in organisms, cell-cell adhesion adapt to external mechanical cues arising from the static environment of cells and from dynamic interactions between neighboring cells. Cell-cell adhesions need to resist detachment forces to secure the integrity and internal organization of organisms. In the past, various techniques have been developed to characterize adhesion properties of molecules and cells in vitro, and to understand how cells sense and probe their environment. Atomic force microscopy and dual-pipette aspiration, where cells are mainly present in suspension, are common methods for studying detachment forces of cell-cell adhesions. How cell-cell adhesion forces are developed for adherent and environment-adapted cells, however, is less clear. Here, we designed the Cell-Cell Separation Device (CC-SD), a microstructured substrate that measures both intercellular forces and external stresses of cells towards the matrix. The design is based on micropillar arrays originally designed for cell traction-force measurements. We designed PDMS micropillar-blocks, to which cells could adhere and be able to connect to each other across the gap. Controlled stretching of the whole substrate changed the distance between blocks and increased gap size. That allowed us to apply strains to cell-cell contacts, eventually leading to cell-cell adhesion detachment, which was measured by pillar deflections. The CC-SD provided an increase of the gap between the blocks of up to 2.4-fold, which was sufficient to separate substrate-attached cells with fully developed F-actin network. Simultaneously measured pillar deflections allowed us to address cellular response to the intercellular strain applied. The CC-SD thus opens up possibilities for the analysis of intercellular force detachments and sheds light on the robustness of cell-cell adhesions in dynamic processes in tissue development.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2023)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.
Parametric anti-resonance is a phenomenon that occurs in systems with at least two degrees of freedom; this can be achieved by periodically exciting some parameters of the system. The effect of this properly tuned periodicity is to increase the dissipation in the system, which leads to a raising in the effective damping of vibrations. This contribution presents the design of an open-loop control to reduce the settling time using the anti-resonance concept. The control signal consists of a quasi-periodic signal capable of transferring the system’s oscillations from one mode to another mode of the system. The general averaging technique is used to characterize the dynamics, particularly the so-called slow dynamics of motion. With this analysis, the control signal is designed for the potential application of a microelectromechanical sensor arrangement; for this specific example, up to 96.8% reduction of settling time is achieved.
In this work, parametric excitation is introduced in a fully balanced flexible rotor mounted on two identical active gas foil bearings. The active gas foil bearings change the top foil shape harmonically with a specific amplitude and frequency. The deformable foil shape is approximated by an analytical function, while the gas pressure distribution is evaluated by the numerical solution of the Reynolds equation for compressible flow. The harmonic variation of the foil shape generates a respective variation in the bearings’ stiffness and damping properties and the system experiences parametric resonances and antiresonances in specific excitation frequencies. The nonlinear gas bearing forces generate bifurcations in the solutions of the system at certain rotating speeds and excitation frequencies; period doubling and Neimark-Sacker bifurcations are noticed in the examined system, and their progress is evaluated as the two bifurcation parameters (rotating speed and parametric excitation frequency) are changed, though a codimension-2 numerical continuation of limit cycles. It is found that at specific range of excitation frequency there are parametric anti-resonances and the bifurcations collide and vanish. Therefore, a bifurcation-free operating range is established and the system can operate stable at a wide speed range.
The main aims of this work are the validation of the developed process of gluing a single-mode optical fiber array with a photonic chip and the selection of a more suitable adhesive from the two adhesives being compared. An active alignment system was used for adjusting the two optical fiber arrays to a photonics chip. The gluing was done by two compared UV curable adhesives applied in the optical path. The insertion losses of glued coupling were measured and investigated at two discrete wavelengths 1310 nm and 1550 nm during temperature testing in the climatic chamber according to Telcordia GR_1209_Corei04 [3]. The measurement, investigation, and comparison of insertion losses of the glued coupling at the spectral band from 1530 nm to 1570 nm were done immediately after gluing process and after three temperature cycles in the climatic chamber with one month delay.