Refine
Year of publication
- 2023 (47) (remove)
Document Type
- Article (47) (remove)
Institute
- Wirtschaft (16)
- Forschungszentrum Mikrotechnik (10)
- Soziales & Gesundheit (8)
- Forschungszentrum Business Informatics (4)
- Forschungszentrum Human Centred Technologies (4)
- Forschungszentrum Energie (3)
- Forschung (2)
- Josef Ressel Zentrum für Intelligente Thermische Energiesysteme (2)
- Forschungsgruppe Empirische Sozialwissenschaften (1)
- Gestaltung (1)
Keywords
- Schreibdidaktik (3)
- Business Analytics (2)
- Controlling (2)
- Excel (2)
- Prognose (2)
- Zeitreihenanalyse (2)
- AWG (1)
- AWG-spectrometer (1)
- Akademisierung (1)
- Anthropocentrism (1)
Pooled data from published reports on infants with clinically diagnosed vitamin B12 (B12) deficiency were analyzed with the purpose of describing the presentation, diagnostic approaches, and risk factors for the condition to inform prevention strategies. An electronic (PubMed database) and manual literature search following the PRISMA approach was conducted (preregistration with the Open Science Framework, accessed on 15 February 2023). Data were described and analyzed using correlation analyses, Chi-square tests, ANOVAs, and regression analyses, and 102 publications (292 cases) were analyzed. The mean age at first symptoms (anemia, various neurological symptoms) was four months; the mean time to diagnosis was 2.6 months. Maternal B12 at diagnosis, exclusive breastfeeding, and a maternal diet low in B12 predicted infant B12, methylmalonic acid, and total homocysteine. Infant B12 deficiency is still not easily diagnosed. Methylmalonic acid and total homocysteine are useful diagnostic parameters in addition to B12 levels. Since maternal B12 status predicts infant B12 status, it would probably be advantageous to target women in early pregnancy or even preconceptionally to prevent infant B12 deficiency, rather than to rely on newborn screening that often does not reliably identify high-risk children.
Redundanz und Varietät
(2023)
Ausrechnen oder aushandeln?
(2023)
Das Kreisgespräch
(2023)
Formen des Dialogs
(2023)
Die persönliche Black-Box
(2023)
Der Schlüssel zur Zukunft
(2023)
Background: Cardiovascular disease is the major cause of death worldwide. Although knowledge regarding diagnosing and treating cardiovascular disease has increased dramatically, secondary prevention remains insufficiently implemented due to failure among affected individuals to adhere to guideline recommendations. This has continued to lead to high morbidity and mortality rates. Involving patients in their healthcare and facilitating their active roles in their chronic disease management is an opportunity to meet the needs of the increasing number of cardio-vascular patients. However, simple recall of advice regarding a more preventive lifestyle does not affect sustainable behavioral lifestyle changes. We investigate the effect of plaque visualization combined with low-threshold daily lifestyle tasks using the smartphone app PreventiPlaque to evaluate change in cardiovascular risk profile. Methods: and study design: This randomized, controlled clinical trial includes 240 participants with ultrasound evidence of atherosclerotic plaque in one or both carotid arteries, defined as focal thickening of the vessel wall measuring 50% more than the regular vessel wall. A criterion for participation is access to a smartphone suitable for app usage. The participants are randomly assigned to an intervention or a control group. While both groups receive the standard of care, the intervention group has additional access to the PreventiPlaque app during the 12-month follow-up. The app includes daily tasks that promote a healthier lifestyle in the areas of smoking cessation, medication adherence, physical activity, and diet. The impact of plaque visualization and app use on the change in cardiovascular risk profile is assessed by SCORE2. Feasibility and effectiveness of the PreventiPlaque app are evaluated using standardized and validated measures for patient feedback.
We present design of planar 16-channel, 100-GHz multi-mode polymer-based AWG. This AWG was designed for central wavelength of 1550 nm applying AWG-Parameters tool. The AWG structure was created and simulated in the commercial photonic tool PHASAR from Optiwave. Achieved transmission characteristics were evaluated by AWG-Analyzer tool. For the design, multi-mode waveguides having a cross-section of (4x4) µm2 were used. The simulated results show strong worsening of the transmission characteristics in comparison when using single-mode waveguides. Nevertheless, the transmitting channels are clearly separated. The reason for using thicker multi-mode waveguides in the design is possibility to fabricate the AWG structure on polymer basis using direct laser writing lithography.
This paper presents design, simulation, and optimization of the three-dimensional 1×4 optical multimode interference splitter using IP-Dip polymer as a core and polydimethylsiloxane (PDMS) Sylgard 184 as a cladding. The splitter was simulated by using beam propagation method in BeamPROP simulation engine of RSoft photonic tool and optimized for an operating wavelength of 1.55 µm. According to the minimum insertion loss, the dimensions of the MMI coupler and the length of the whole MMI splitter structure were optimized applying a waveguide with a core size of 4×4 µm2. The objective of the study is to create a design for fabrication by three-dimensional direct laser writing optical lithography.
A model is presented that allows for the calculation of the success probability by which a vanilla Evolution Strategy converges to the global optimizer of the Rastrigin test function. As a result a population size scaling formula will be derived that allows for an estimation of the population size needed to ensure a high convergence security depending on the search space dimensionality.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2023)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.