Refine
Year of publication
Document Type
- Article (70) (remove)
Institute
- Forschungszentrum Mikrotechnik (24)
- Forschungszentrum Energie (14)
- Forschungszentrum Business Informatics (11)
- Soziales & Gesundheit (10)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (8)
- Technik | Engineering & Technology (8)
- Forschungszentrum Human Centred Technologies (5)
- Wirtschaft (3)
- Forschungszentrum Digital Factory Vorarlberg (1)
- Gestaltung (1)
Has Fulltext
- yes (70) (remove)
Keywords
- Peripheral arterial disease (3)
- Y-branch splitter (3)
- Bubble column humidifier (2)
- Demand response (2)
- Demand side management (2)
- Desalination (2)
- Distribution grids (2)
- Energy storage (2)
- Humidification-dehumidification (2)
- Power tracking (2)
Traditional power grids are mainly based on centralized power generation and subsequent distribution. The increasing penetration of distributed renewable energy sources and the growing number of electrical loads is creating difficulties in balancing supply and demand and threatens the secure and efficient operation of power grids. At the same time, households hold an increasing amount of flexibility, which can be exploited by demand-side management to decrease customer cost and support grid operation. Compared to the collection of individual flexibilities, aggregation reduces optimization complexity, protects households’ privacy, and lowers the communication effort. In mathematical terms, each flexibility is modeled by a set of power profiles, and the aggregated flexibility is modeled by the Minkowski sum of individual flexibilities. As the exact Minkowski sum calculation is generally computationally prohibitive, various approximations can be found in the literature. The main contribution of this paper is a comparative evaluation of several approximation algorithms in terms of novel quality criteria, computational complexity, and communication effort using realistic data. Furthermore, we investigate the dependence of selected comparison criteria on the time horizon length and on the number of households. Our results indicate that none of the algorithms perform satisfactorily in all categories. Hence, we provide guidelines on the application-dependent algorithm choice. Moreover, we demonstrate a major drawback of some inner approximations, namely that they may lead to situations in which not using the flexibility is impossible, which may be suboptimal in certain situations.
We have investigated the ablation behaviour of single crystal SrTiO3 <100> with focus on the influence of the pulse duration at a wavelength of 248 nm. The experiments were performed with KrF-excimer lasers with pulse durations of 34 ns and 500 fs, respectively. Femtosecond-ablation turns out to be more efficient by one order of magnitude and to eliminate the known problem of cracking of SrTiO3 during laser machining with longer pulses. In addition, the cavities ablated with femtosecond pulses display a smoother surface with no indication of melting and well-defined, sharp edges. These effects can be explained by the reduced thermal shock effect on the material by using ultrashort pulses.
Adult muscle carnitine palmitoyltransferase (CPT) II deficiency is a rare autosomal recessive disorder of long-chain fatty acid metabolism. It is typically associated with recurrent episodes of exercise-induced rhabdomyolysis and myoglobinuria, in most cases caused by a c.338C > T mutation in the CPT2 gene. Here we present the pedigree of one of the largest family studies of CPT II deficiency caused by the c.338C > T mutation, documented so far. The pedigree comprises 24 blood relatives
of the index patient, a 32 year old female with genetically proven CPT II deficiency. In total, the mutation was detected in 20 family members, among them five homozygotes and 15 heterozygotes. Among all homozygotes, first symptoms of CPT II deficiency occurred during childhood. Additionally, two already deceased relatives of the index patient were carriers of at least one copy of the genetic variant, revealing a remarkably high prevalence of the c.338C > T mutation within the tested family. Beside the index patient, only one individual had been diagnosed with CPT II deficiency prior to this study and three cases of CPT II deficiency were newly detected by this family study, pointing
to a general underdiagnosis of the disease. Therefore, this study emphasizes the need to raise awareness of CPT II deficiency for correct diagnosis and accurate management of the disease.
Pooled data from published reports on infants with clinically diagnosed vitamin B12 (B12) deficiency were analyzed with the purpose of describing the presentation, diagnostic approaches, and risk factors for the condition to inform prevention strategies. An electronic (PubMed database) and manual literature search following the PRISMA approach was conducted (preregistration with the Open Science Framework, accessed on 15 February 2023). Data were described and analyzed using correlation analyses, Chi-square tests, ANOVAs, and regression analyses, and 102 publications (292 cases) were analyzed. The mean age at first symptoms (anemia, various neurological symptoms) was four months; the mean time to diagnosis was 2.6 months. Maternal B12 at diagnosis, exclusive breastfeeding, and a maternal diet low in B12 predicted infant B12, methylmalonic acid, and total homocysteine. Infant B12 deficiency is still not easily diagnosed. Methylmalonic acid and total homocysteine are useful diagnostic parameters in addition to B12 levels. Since maternal B12 status predicts infant B12 status, it would probably be advantageous to target women in early pregnancy or even preconceptionally to prevent infant B12 deficiency, rather than to rely on newborn screening that often does not reliably identify high-risk children.
Over the last years, polymers have gained great attention as substrate material, because of the possibility to produce low-cost sensors in a high-throughput manner or for rapid prototyping and the wide variety of polymeric materials available with different features (like transparency, flexibility, stretchability, etc.). For almost all biosensing applications, the interaction between biomolecules (for example, antibodies, proteins or enzymes) and the employed substrate surface is highly important. In order to realize an effective biomolecule immobilization on polymers, different surface activation techniques, including chemical and physical methods, exist. Among them, plasma treatment offers an easy, fast and effective activation of the surfaces by micro/nanotexturing and generating functional groups (including carboxylic acids, amines, esters, aldehydes or hydroxyl groups). Hence, here we present a systematic and comprehensive plasma activation study of various polymeric surfaces by optimizing different parameters, including power, time, substrate temperature and gas composition. Thereby, the highest immobilization efficiency along with a homogenous biomolecule distribution is achieved with a 5-min plasma treatment under a gas composition of 50% oxygen and nitrogen, at a power of 1000 W and a substrate temperature of 80 C. These results are also confirmed by different surface characterization methods, including SEM, XPS and contact angle measurements.
The importance of Agent-Based Simulation (ABS) as scientific method to generate data for scientific models in general and for informed policy decisions in particular has been widely recognised. However, the important technique of code testing of implementations like unit testing has not generated much research interested so far. As a possible solution, in previous work we have explored the conceptual use of property-based testing. In this code testing method, model specifications and invariants are expressed directly in code and tested through automated and randomised test data generation. This paper expands on our previous work and explores how to use property-based testing on a technical level to encode and test specifications of ABS. As use case the simple agent-based SIR model is used, where it is shown how to test agent behaviour, transition probabilities and model invariants. The outcome are specifications expressed directly in code, which relate whole classes of random input to expected classes of output. During test execution, random test data is generated automatically, potentially covering the equivalent of thousands of unit tests, run within seconds on modern hardware. This makes property-based testing in the context of ABS strictly more powerful than unit testing, as it is a much more natural fit due to its stochastic nature.
Investigation of non-uniformly emitting optical fiber diffusers on the light distribution in tissue
(2020)
In recent years, ultrashort pulsed lasers have increased their applicability for industrial requirements, as reliable femtosecond and picosecond laser sources with high output power are available on the market. Compared to conventional laser sources, high quality processing of a large number of material classes with different mechanical and optical properties is possible. In the field of laser cutting, these properties enable the cutting of multilayer substrates with changing material properties. In this work, the femtosecond laser cutting of phosphor sheets is demonstrated. The substrate contains a 230 micrometer thick silicone layer filled with phosphor, which is embedded between two glass plates. Due to the softness and thermal sensitivity of the silicone layer in combination with the hard and brittle dielectric material, the separation of such a material combination is challenging for both mechanical separation processes and cutting with conventional laser sources. In our work, we show that the femtosecond laser is suitable to cut the substrate with a high cutting edge quality. In addition to the experimental results of the laser dicing process, we present a universal model that allows predicting the final cutting edge geometry of a multilayer substrate.
We present the technological verification of a size-optimized 160-channel, 50-GHz silicon nitride-based AWG-spectrometer. The spectrometer was designed for TM-polarized light with a central wavelength of 850 nm applying our proprietary “AWG-Parameters” tool. For the simulations of AWG layout, the WDM PHASAR photonics tool from Optiwave was used. The simulated results show satisfying optical properties of the designed AWG-spectrometer. However, the high-channel count causes a large AWG size with standard design approaches. To solve this problem we designed a special taper enabling the reduction of AWG structure by about 15% while keeping the same optical properties. The AWG design was fabricated and the measured spectra not only confirm the proposed size-reduction but also the improvement of optical properties of the size-optimized AWG.
Today, optics and photonics is widely regarded as one of the most important key technologies for this century. Many experts even anticipate that the 21st century will be century of photon much as the 20th century was the century of electron. Optics and photonics technologies affect almost all areas of our life and cover a wide range of applications in science and industry, e.g. in information and communication technology, in medicine, life science engineering as well as in energy and environmental technology. However even so attractive, the photonics is not well known by most people. To motivate especially young generation for optics and photonics we worked out a lecture related to the “light” for children aged eight to twelve years. We have prepared many experiments to explain the nature of light and its applications in our everyday life. Finally, we focused on the optical data transmission, i.e. how modern communication over optical networks works. To reach many children at home we recorded this lecture and offered it as a video online in the frame of children’s university at Vorarlberg University of Applied Sciences. By combining the hands-on teaching with having a fun while learning about the basic optics concepts we aroused interest of many children with a very positive feedback.
In this paper, low-loss Y-branch splitters up to 128 splitting ratio are designed, simulated, and optimized by using 2D beam propagation method in OptiBPM tool by Optiwave. For an optical waveguide, a silica-on-silicon material platform is used. The splitters were designed as a planar structure for a telecommunication operating wavelength of 1.55 m. According to the minimum insertion loss and minimum non-uniformity, the optimum length for each Y-branch is determined. The influence of the pre-defined S-Bend waveguide shapes (Arc, Cosine, Sine) and of the waveguide core size reduction on the splitter performance has been also studied. The obtained simulation results of all designed splitters with different S-Bend shape waveguides together with the different waveguide core sizes are discussed and compared with each other.
Design and optimization of 1x2N Y-branch optical splitters for telecommunication applications
(2020)
This paper presents the design and optimization of 1x2N Y-branch optical splitters for telecom applications. A waveguide channel profile, used in the splitter design, is based on a standard silica-on-silicon material platform. Except for the lengths of the used Y-branches, design parameters such as port pitch between the waveguides and simulation parameters for all splitters were considered fixed. For every Y-branch splitter, insertion loss, non-uniformity, and background crosstalk are calculated. According to the minimum insertion loss and minimum non-uniformity, the optimum length for each Y-branch is determined. Finally, the individual Y-branches are cascade joined to design various Y-branch optical splitters, from 1x2 to 1x64.
A model is presented that allows for the calculation of the success probability by which a vanilla Evolution Strategy converges to the global optimizer of the Rastrigin test function. As a result a population size scaling formula will be derived that allows for an estimation of the population size needed to ensure a high convergence security depending on the search space dimensionality.
Electric cell-substrate impedance spectroscopy (ECIS) enables non-invasive and continuous read-out of electrical parameters of living tissue. The aim of the current study was to investigate the performance of interdigitated sensors with 50 μm electrode width and 50 μm inter-electrode distance made of gold, aluminium, and titanium for monitoring the barrier properties of epithelial cells in tissue culture. At first, the measurement performance of the photolithographic fabricated sensors was characterized by defined reference electrolytes. The sensors were used to monitor the electrical properties of two adherent epithelial barrier tissue models: renal proximal tubular LLC-PK1 cells, representing a normal functional transporting epithelium, and human cervical cancer-derived HeLa cells, forming non-transporting cancerous epithelial tissue. Then, the impedance spectra obtained were analysed by numerically fitting the parameters of the two different models to the measured impedance spectrum. Aluminium sensors proved to be as sensitive and consistent in repeated online-recordings for continuous cell growth and differentiation monitoring assensors made of gold, the standard electrode material. Titanium electrodes exhibited an elevated intrinsic ohmic resistance incomparison to gold reflecting its lower electric conductivity. Analysis of impedance spectra through applying models and numerical data fitting enabled the detailed investigation of the development and properties of a functional transporting epithelial tissue using either gold or aluminium sensors. The result of the data obtained, supports the consideration of aluminium and titanium sensor materials as potential alternatives to gold sensors for advanced application of ECIS spectroscopy.
In the regime of incentive-based autonomous demand response, time dependent prices are typically used to serve as signals from a system operator to consumers. However, this approach has been shown to be problematic from various perspectives. We clarify these shortcomings in a geometric way and thereby motivate the use of power signals instead of price signals. The main contribution of this paper consists of demonstrating in a standard setting that power tracking signals can control flexibilities more efficiently than real-time price signals. For comparison by simulation, German renewable energy production and German standard load profiles are used for daily production and demand profiles, respectively. As for flexibility, an energy storage system with realistic efficiencies is considered. Most critically, the new approach is able to induce consumptions on the demand side that real-time pricing is unable to induce. Moreover, the pricing approach is outperformed with regards to imbalance energy, peak consumption, storage variation, and storage losses without the need for additional communication or computation efforts. It is further shown that the advantages of the optimal power tracking approach compared to the pricing approach increase with the extent of the flexibility. The results indicate that autonomous flexibility control by optimal power tracking is able to integrate renewable energy production efficiently, has additional benefits, and the potential for enhancements. The latter include data uncertainties, systems of flexibilities, and economic implementation.
In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.
Lead–magnesium niobate lead titanate (PMN-PT) has been proven as an excellent material for sensing and actuating applications. The fabrication of advanced ultra-small PMN-PT-based devices relies on the availability of sophisticated procedures for the micro-machining of PMN-PT thin films or bulk substrates. Approaches reported up to date include chemical etching, excimer laser ablation, and ion milling. To ensure an excellent device performance, a key mandatory feature for a micro-machining process is to preserve as far as possible the crystalline quality of the substrates; in other words, the fabrication method must induce a low density of cracks and other kind of defects. In this work, we demonstrate a relatively fast procedure for the fabrication of high-quality PMN-PT micro-machined actuators employing green femtosecond laser pulses. The fabricated devices feature the absence of extended cracks and well-defined edges with relatively low roughness, which is advantageous for the further integration of nanomaterials onto the piezoelectric actuators.