Refine
Year of publication
Document Type
- Article (450) (remove)
Institute
- Wirtschaft (134)
- Forschungszentrum Mikrotechnik (104)
- Forschungszentrum Business Informatics (67)
- Technik | Engineering & Technology (55)
- Department of Computer Science (Ende 2021 aufgelöst; Integration in die übergeordnete OE Technik) (54)
- Forschungszentrum Energie (51)
- Soziales & Gesundheit (51)
- Forschungsgruppe Empirische Sozialwissenschaften (22)
- Didaktik (mit 31.03.2021 aufgelöst; Integration ins TELL Center) (20)
- Josef Ressel Zentrum für Materialbearbeitung (15)
Language
- English (288)
- German (160)
- Multiple languages (2)
Keywords
- Laser ablation (8)
- Entscheidung (6)
- Evolution strategy (5)
- Schreibdidaktik (5)
- Soziale Arbeit (5)
- Volatile organic compounds (5)
- Y-branch splitter (5)
- Ausscheidung (4)
- Demand side management (4)
- Organisation (4)
We present a new concept of 3D polymer-based 1 × 4 beam splitter for wavelength splitting around 1550 nm. The beam splitter consists of IP-Dip polymer as a core and polydimethylsiloxane (PDMS) Sylgard 184 as a cladding. The splitter was designed and simulated with two different photonics tools and the results show high splitting ratio for single-mode and multi-mode operation with low losses. Based on the simulations, a 3D beam splitter was designed and realized using direct laser writing (DLW) process with adaptation to coupling to standard single-mode fiber. With respect to the technological limits, the multi-mode splitter having core of (4 × 4) μm 2 was designed and fabricated together with supporting stable mechanical construction. Splitting properties were investigated by intensity monitoring of splitter outputs using optical microscopy and near-field scanning optical microscopy. In the development phase, the optical performance of fabricated beam splitter was examined by splitting of short visible wavelengths using red light emitting diode. Finally, the splitting of 1550 nm laser light was studied in detail by near-field measurements and compared with the simulated results. The nearly single-mode operation was observed and the shape of propagating mode and mode field diameter was well recognized.
Recently the use of microRNAs (miRNAs) as biomarkers for a multitude of diseases has gained substantial significance for clinical as well as point-of-care diagnostics. Amongst other challenges, however, it holds the central requirement that the concentration of a given miRNA must be evaluated within the context of other factors in order to unambiguously diagnose one specific disease. In terms of the development of diagnostic methods and devices, this implies an inevitable demand for multiplexing in order to be able to gauge the abundance of several components of interest in a patient’s sample in parallel. In this study, we design and implement different multiplexed versions of our electrochemical microfluidic biosensor by dividing its channel into subsections, creating four novel chip designs for the amplification-free and simultaneous quantification of up to eight miRNAs on the CRISPR-Biosensor X (‘X’ highlighting the multiplexing aspect of the device). We then use a one-step model assay followed by amperometric readout in combination with a 2-minute-stop-flow-protocol to explore the fluidic and mechanical characteristics and limitations of the different versions of the device. The sensor showing the best performance, is subsequently used for the Cas13a-powered proof-of-concept measurement of two miRNAs (miRNA-19b and miRNA-20a) from the miRNA-17∼92 cluster, which is dysregulated in the blood of pediatric medulloblastoma patients. Quantification of the latter, alongside simultaneous negative control measurements are accomplished on the same device. We thereby confirm the applicability of our platform to the challenge of amplification-free, parallel detection of multiple nucleic acids.
In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.
If left uncontrolled, electric vehicle charging poses severe challenges to distribution grid operation. Resulting issues are expected to be mitigated by charging control. In particular, voltage-based charging control, by relying only on the local measurements of voltage at the point of connection, provides an autonomous communication-free solution. The controller, attached to the charging equipment, compares the measured voltage to a reference voltage and adapts the charging power using a droop control characteristic. We present a systematic study of the voltage-based droop control method for electric vehicles to establish the usability of the method for all the currently available residential electric vehicle charging possibilities considering a wide range of electric vehicle penetrations. Voltage limits are evaluated according to the international standard EN50160, using long-term load flow simulations based on a real distribution grid topology and real load profiles. The results achieved show that the voltage-based droop controller is able to mitigate the under voltage problems completely in distribution grids in cases either deploying low charging power levels or exhibiting low penetration rates. For high charging rates and high penetrations, the control mechanism improves the overall voltage profile, but it does not remedy the under voltage problems completely. The evaluation also shows the controller’s ability to reduce the peak power at the transformer and indicates the impact it has on users due to the reduction in the average charging rates. The outcomes of the paper provide the distribution grid operators an insight on the voltage-based droop control mechanism for the future grid planning and investments.
Background: Mobile health interventions are intended to support complex health care needs in chronic diseases digitally, but they are mainly targeted at general health improvement and neglect disease-specific requirements. Therefore, we designed TrackPAD, a smartphone app to support supervised exercise training in patients with peripheral arterial disease.
Objective: This pilot study aimed to evaluate changes in the 6-minute walking distance (meters) as a primary outcome measure. The secondary outcome measures included changes in physical activity and assessing the patients’ peripheral arterial disease–related quality of life.
Methods: This was a pilot two-arm, single-blinded, randomized controlled trial. Patients with symptomatic PAD (Fontaine stage IIa/b) and access to smartphones were eligible. Eligible participants were randomly assigned to the study, with the control group stratified by the distance covered in the 6-minute walking test using the TENALEA software. Participants randomized to the intervention group received usual care and the mobile intervention (TrackPAD) for the follow-up period of 3 months, whereas participants randomized to the control group received routine care only. TrackPAD records the frequency and duration of training sessions and pain levels using manual user input. Clinical outcome data were collected at the baseline and after 3 months via validated tools (the 6-minute walk test and self-reported quality of life). The usability and quality of the app were determined using the Mobile Application Rating Scale user version.
Results: The intervention group (n=19) increased their mean 6-minute walking distance (83 meters, SD 72.2), while the control group (n=20) decreased their mean distance after 3 months of follow-up (–38.8 meters, SD 53.7; P=.01). The peripheral arterial disease–related quality of life increased significantly in terms of “symptom perception” and “limitations in physical functioning.” Users’ feedback showed increased motivation and a changed attitude toward performing supervised exercise training.
Conclusions: Besides the rating providing a valuable support tool for the user group, the mobile intervention TrackPAD was linked to a change in prognosis-relevant outcome measures combined with enhanced coping with the disease. The influence of mobile interventions on long-term prognosis must be evaluated in the future.
In this paper, the design of three-dimensional configuration of Y-branch splitter is compared with Multimode Interference splitter. Both splitters use the IP-Dip polymer as a standard material for 3D laser lithography. The optical properties of the splitters for both approaches are discussed and compared.
The paper deals with designing and numerical modelling a 2 x 2 optical switch for photonic integrated circuits based on 2 x 2 MMI elements and phase modulators. The 2 x 2 optical switch was modelled in the RsoftCAD with the simulation tool BeamPROP. The 2 x 2 optical switch is a common element for creating more complex 1 x N or N x N optical switches in all-optical signal processing.
In this work, we investigated the influence of different etch depths of the rib waveguides on the performance of SiN-based AWGs. For this purpose, an 8-channel 100 GHz AWG was designed for a center wavelength of 850 nm. The design parameters entered were calculated using the AWG-Parameters tool. The simulations were performed with a commercial photonic tool PHASAR from Optiwave. The simulated performance was evaluated using the AWG-Analyzer tool. For the AWG design, we used three identical rib waveguides with different etch depths to simulate possible etch imperfection. The simulations show the wavelength shift and degradation of the AWG performance.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2022)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
Grid-scale electrical energy storage (EES) is a key component in cost-effective transition scenarios to renewable energy sources. The requirement of scalability favors EES approaches such as pumped-storage hydroelectricity (PSH) or compressed-air energy storage (CAES), which utilize the cheap and abundant storage materials water and air, respectively. To overcome the site restriction and low volumetric energy densities attributed to PSH and CAES, liquid-air energy storage (LAES) has been devised; however, it suffers from a rather small round-trip efficiency (RTE) and challenging storage conditions. Aiming to overcome these drawbacks, a novel system for EES is developed using solidified air (i.e., clathrate hydrate of air) as the storable phase of air. A reference plant for solidified-air energy storage (SAES) is conceptualized and modeled thermodynamically using the software CoolProp for water and air as well as empirical data and first-order approximations for the solidified air (SA). The reference plant exhibits a RTE of 52% and a volumetric storage density of 47 kWh per m3 of SA. While this energy density relates to only one half of that in LAES plants, the modeled RTE of SAES is comparable already. Since improved thermal management and the use of thermodynamic promoters can further increase the RTEs in SAES, the technical potential of SAES is in place already. Yet, for a successful implementation of the concept - in addition to economic aspects - questions regarding the stability of SA must be first clarified and challenges related to the processing of SA resolved.
Bubble columns are recently used for the humidification of air in water treatment systems and fuel cells. They are well applicable due to their excellent heat and mass transfer and their low technical complexity. To design and operate such devices with high efficiency, the humidification process and the impact of the operating parameters need to be understood to a sufficient degree. To extend this knowledge, we use a refined and novel method to determine the volumetric air–liquid heat and mass transfer coefficients and the humidifier efficiency for various parametric settings. The volumetric transfer coefficients increase with both of the superficial air velocity and the liquid temperature. It is further shown that the decrease of vapor pressure with an increase of the salinity results in a corresponding decrease in the outlet humidity ratio. In contrast to previous studies, liquid heights smaller than 0.1 m are investigated and significant changes in the humidifier efficiency are seen in this range. We present the expected humidifier efficiency with respect to the superficial air velocity and the liquid height in an efficiency chart, such that optimal operating conditions can be determined. Based on this efficiency chart, recommendations for industrial applications as well as future scientific challenges are drawn.
The production of liquid-gas dispersions places high demands on the process technology, which requires knowledge of the bubble formation mechanisms, as well as the phase parameters of the media combinations used. To obtain the bubble sizes introduced to a flow not knowing the phase parameters, different process parameters are investigated. Their quality and applicability are evaluated. The results obtained make it possible to simplify long design processes of dispersion processes in manufacturing plants and to ensure the product quality of the products manufactured, by reducing waste.
Violation-mitigation-based method for PV hosting capacity quantification in low voltage grids
(2022)
Hosting capacity knowledge is of great importance for distribution utilities to assess the amount of PV capacity possible to accommodate without troubling the operation of the grid. In this paper, a novel method to quantify the hosting capacity of low voltage grids is presented. The method starts considering a state of fully exploited building rooftop solar potential. A downward process is proposed - from the starting state with expected violations on the grid operation to a state with no violations. In this process, the installed PV capacity is progressively reduced. The reductions are made sequentially and selectively aiming to mitigate specific violations: nodes overvoltage, lines overcurrent and transformer overloading. Evaluated on real data of fourteen low voltage grids from Austria, the method proposed exhibits benefits in terms of higher hosting capacities and lower computational costs compared to stochastic methods. Furthermore, it also quantifies hosting capacity expansions achievable by overcoming the effect of the violations. The usage of a potential different from solar rooftops is also presented, demonstrating that a user-defined potential allows to quantify the hosting capacity in a more general setting with the method proposed.
Sie werden beobachtet
(2022)
Wahrheit braucht Vertrauen
(2022)
Die Arbeitswelt von morgen
(2022)