Refine
Year of publication
- 2023 (16) (remove)
Document Type
- Article (10)
- Conference Proceeding (4)
- Preprint (2)
Institute
- Forschungszentrum Mikrotechnik (16) (remove)
Language
- English (16)
Keywords
- photonics (2)
- 3D MMI splitter (1)
- AWG (1)
- AWG design (1)
- AWG-spectrometer (1)
- Excited States (1)
- Hot States (1)
- Levodopa (1)
- MEMS (1)
- MMI splitter (1)
In this paper, a 256-channel, 10-GHz arrayed waveguide gratings demultiplexer for ultra-dense wavelength division multiplexing was designed using an in-house developed tool called AWG-Parameters. The AWG demultiplexer was designed for a central wavelength of 1550 nm and the structure was simulated in PHASAR tool from Optiwave. Two different AWG designs were developed and the influence of the design parameters on the AWG performance was studied.
We present design of planar 16-channel, 100-GHz multi-mode polymer-based AWG. This AWG was designed for central wavelength of 1550 nm applying AWG-Parameters tool. The AWG structure was created and simulated in the commercial photonic tool PHASAR from Optiwave. Achieved transmission characteristics were evaluated by AWG-Analyzer tool. For the design, multi-mode waveguides having a cross-section of (4x4) µm2 were used. The simulated results show strong worsening of the transmission characteristics in comparison when using single-mode waveguides. Nevertheless, the transmitting channels are clearly separated. The reason for using thicker multi-mode waveguides in the design is possibility to fabricate the AWG structure on polymer basis using direct laser writing lithography.
This paper presents design, simulation, and optimization of the three-dimensional 1×4 optical multimode interference splitter using IP-Dip polymer as a core and polydimethylsiloxane (PDMS) Sylgard 184 as a cladding. The splitter was simulated by using beam propagation method in BeamPROP simulation engine of RSoft photonic tool and optimized for an operating wavelength of 1.55 µm. According to the minimum insertion loss, the dimensions of the MMI coupler and the length of the whole MMI splitter structure were optimized applying a waveguide with a core size of 4×4 µm2. The objective of the study is to create a design for fabrication by three-dimensional direct laser writing optical lithography.
Design, simulation, and optimization of the 1×4 optical three-dimensional multimode interference splitter using IP-Dip polymer as a core and polydimethylsiloxane (PDMS) Sylgard 184 as a cladding is demonstrated. The splitter was simulated by using beam propagation method in BeamPROP simulation module of RSoft photonic tool and optimized for an operating wavelength of 1.55 μm . According to the minimum insertion loss, the dimensions of the splitter were optimized for a waveguide with a core size of 4×4 μm2 . The objective of the study is to create the design for fabrication by three-dimensional direct laser writing optical lithography.
Strain-induced dynamic control over the population of quantum emitters in two-dimensional materials
(2023)
The discovery of quantum emitters in two-dimensional materials has triggered a surge of research to assess their suitability for quantum photonics. While their microscopic origin is still the subject of intense studies, ordered arrays of quantum emitters are routinely fabricated using static strain-gradients, which are used to drive excitons toward localized regions of the 2D crystals where quantum-light-emission takes place. However, the possibility of using strain in a dynamic fashion to control the appearance of individual quantum emitters has never been explored so far. In this work, we tackle this challenge by introducing a novel hybrid semiconductor-piezoelectric device in which WSe2 monolayers are integrated onto piezoelectric pillars delivering both static and dynamic strains. Static strains are first used to induce the formation of quantum emitters, whose emission shows photon anti-bunching. Their excitonic population and emission energy are then reversibly controlled via the application of a voltage to the piezoelectric pillar. Numerical simulations combined with drift-diffusion equations show that these effects are due to a strain-induced modification of the confining-potential landscape, which in turn leads to a net redistribution of excitons among the different quantum emitters. Our work provides relevant insights into the role of strain in the formation of quantum emitters in 2D materials and suggests a method to switch them on and off on demand.
Parametric anti-resonance is a phenomenon that occurs in systems with at least two degrees of freedom; this can be achieved by periodically exciting some parameters of the system. The effect of this properly tuned periodicity is to increase the dissipation in the system, which leads to a raising in the effective damping of vibrations. This contribution presents the design of an open-loop control to reduce the settling time using the anti-resonance concept. The control signal consists of a quasi-periodic signal capable of transferring the system’s oscillations from one mode to another mode of the system. The general averaging technique is used to characterize the dynamics, particularly the so-called slow dynamics of motion. With this analysis, the control signal is designed for the potential application of a microelectromechanical sensor arrangement; for this specific example, up to 96.8% reduction of settling time is achieved.
Highly-sensitive single-step sensing of levodopa by swellable microneedle-mounted nanogap sensors
(2023)
Microneedle (MN) sensing of biomarkers in interstitial fluid (ISF) can overcome the challenges of self-diagnosis of diseases by a patient, such as blood sampling, handling, and measurement analysis. However, the MN sensing technologies still suffer from poor measurement accuracy due to the small amount of target molecules present in ISF, and require multiple steps of ISF extraction, ISF isolation from MN, and measurement with additional equipment. Here, we present a swellable MN-mounted nanogap sensor that can be inserted into the skin tissue, absorb ISF rapidly, and measure biomarkers in situ by amplifying the measurement signals by redox cycling in nanogap electrodes. We demonstrate that the MN-nanogap sensor measures levodopa (LDA), medication for Parkinson disease, down to 100 nM in an aqueous solution, and 1 μM in both the skin-mimicked gelatin phantom and porcine skin.
X-ray microtomography is a nondestructive, three-dimensional inspection technique applied across a vast range of fields and disciplines, ranging from research to industrial, encompassing engineering, biology, and medical research. Phasecontrast imaging extends the domain of application of x-ray microtomography to classes of samples that exhibit weak attenuation, thus appearing with poor contrast in standard x-ray imaging. Notable examples are low-atomic-number materials, like carbon-fiber composites, soft matter, and biological soft tissues.We report on a compact and cost-effective system for x-ray phase-contrast microtomography. The system features high sensitivity to phase gradients and high resolution, requires a low-power sealed x-ray tube, a single optical element, and fits in a small footprint. It is compatible with standard x-ray detector technologies: in our experiments, we have observed that single-photon counting offered higher angular sensitivity, whereas flat panels provided a larger field of view. The system is benchmarked against knownmaterial phantoms, and its potential for soft-tissue three-dimensional imaging is demonstrated on small-animal organs: a piglet esophagus and a rat heart.We believe that the simplicity of the setupwe are proposing, combined with its robustness and sensitivity, will facilitate accessing quantitative x-ray phase-contrast microtomography as a research tool across disciplines, including tissue engineering, materials science, and nondestructive testing in general.
Beyond the Four-Level Model: Dark and Hot States in Quantum Dots Degrade Photonic Entanglement
(2023)
Entangled photon pairs are essential for a multitude of quantum photonic applications. To date, the best performing solid-state quantum emitters of entangled photons are semiconductor quantum dots operated around liquid-helium temperatures. To favor the widespread deployment of these sources, it is important to explore and understand their behavior at temperatures accessible with compact Stirling coolers. Here we study the polarization entanglement among photon pairs from the biexciton–exciton cascade in GaAs quantum dots at temperatures up to ∼65 K. We observe entanglement degradation accompanied by changes in decay dynamics, which we ascribe to thermal population and depopulation of hot and dark states in addition to the four levels relevant for photon pair generation. Detailed calculations considering the presence and characteristics of the additional states and phonon-assisted transitions support the interpretation. We expect these results to guide the optimization of quantum dots as sources of highly entangled photons at elevated temperatures.
Synthetic polymers, such as polyamide (PA), inherently possess a moderate number of surface functionalities compared to natural polymers, which negatively impacts the uniformity of metallic coatings obtained through wet-chemical methods like electroless plating. The paper presents the use of a siloxane interlayer formed from the condensation of the hydrolyzed 3-triethoxysilylpropyl succinic anhydride (TESPSA) precursor as a strategy to modify the surface properties of polyamide 6.6 (PA66) fabrics and improve the uniformity of the copper surface coating. The application of the siloxane intermediate coating demonstrates a significant improvement in electrical conductivity, up to 20 times higher than fabrics without the interlayer. The morphology of the coatings was investigated using scanning electron (SEM) and laser confocal scanning microscopy (LSM). In addition, dye adsorption, flexural rigidity, air permeability and contact angle measurements were conducted to monitor the change in the PA66 properties after the siloxane functionalization.